We investigated the spatial distribution of S-coda-wave energy in northeastern Honshu, Japan, where a volcanic front runs from north to south. Seismograms of a local event with a magnitude of 6.4 recorded by the Hi-net were analyzed in this study. The mean square amplitudes of coda waves at 82 seismic stations were calculated for bands with frequencies of 2–4, 4–8, 8–16, and 16–32 Hz. From these measurements, a clear spatial variation of coda-wave energy was observed across the volcanic front from east (forearc) to west (backarc). The coda-wave energy is uniformly distributed in the forearc, whereas an exponential decrease with horizontal offset from the volcanic front is found in the backarc. The decay rate increases with increasing frequency.
We propose a diffusion–absorption model to give a physical insight into the observed regional variation in coda-wave energy. This model explains the observed characteristics successfully and predicts that the exponential variation of coda-wave energy in the backarc is a function of the diffusivity and the absorption coefficient. The magnitude of the intrinsic attenuation factor in the backarc is estimated at about Qi–1 = 0.02 at a frequency of 10 Hz by assuming a value of 0.01 km–1 for the scattering coefficient. This intrinsic attenuation factor is about twice as large as those reported from previous studies on the forearc.
Nous avons étudié la distribution spatiale de l'énergie de vague de S-coda dans Honshu du nord-est, Japon, où un avant volcanique fonctionne du nord au sud. Les séismogrammes d'un événement local avec une importance de 6.4 ont enregistré par bonjour le filet ont été analysés dans cette étude. Les amplitudes de moyenne carrée de vagues de coda à 82 stations séismiques ont été calculées pour des bandes avec des fréquences de 2-4, 4-8, 8-16, et 16-32 hertz. De ces mesures, on a observé une variation spatiale claire d'énergie de vague de coda à travers l'avant volcanique de l'est (arc antérieur) à l'ouest (arc arrière). L'énergie de vague de coda est uniformément distribuée dans l'arc antérieur, tandis qu'une diminution exponentielle avec l'excentrage horizontal de l'avant volcanique est trouvée de l'arc arrière. Les augmentations de taux d'affaiblissement avec l'augmentation de la fréquence. Nous proposons un modèle d'absorption de diffusion pour donner une perspicacité physique dans la variation régionale observée de l'énergie de vague de coda. Ce modèle explique les caractéristiques observées avec succès et prévoit que la variation exponentielle de l'énergie de vague de coda dans l'arc arrière est une fonction de la diffusivité et du coefficient d'absorption. L'importance du facteur intrinsèque d'atténuation dans l'arc arrière est estimée à environ Qi-1 = 0.02 à une fréquence de 10 hertz en assumant une valeur de 0.01 km-1 pour le coéfficient de dispersion. Ce facteur intrinsèque d'atténuation est environ deux fois plus grand que ceux rapportés des études précédentes sur l'arc antérieur.
|
DEWEY : |
551.2 |
ISSN : |
0037-1106 |
En ligne : |
http:www.seismosoc.org |
in Bulletin of the seismological society of America > Vol. 96 N° 2 (Avril 2006) . - 637-646 p.
[article] A Volcanic Front as a Boundary of Seismic-Attenuation Structures in Northeastern Honshu, Japan = Un Avant Volcanique comme Frontière des Structures Séismiques d'Atténuation dans Honshu du nord-est, Japon [texte imprimé] / K. Yoshimoto, Auteur ; U. Wegler, Auteur ; M. Korn, Auteur . - 2006 . - 637-646 p. Génie Civil Langues : Anglais ( eng) in Bulletin of the seismological society of America > Vol. 96 N° 2 (Avril 2006) . - 637-646 p.
Mots-clés : |
Séismogrammes Energie Vague Stations séismiques |
Index. décimale : |
551.2 Batholithes gangue.Apophyses |
Résumé : |
We investigated the spatial distribution of S-coda-wave energy in northeastern Honshu, Japan, where a volcanic front runs from north to south. Seismograms of a local event with a magnitude of 6.4 recorded by the Hi-net were analyzed in this study. The mean square amplitudes of coda waves at 82 seismic stations were calculated for bands with frequencies of 2–4, 4–8, 8–16, and 16–32 Hz. From these measurements, a clear spatial variation of coda-wave energy was observed across the volcanic front from east (forearc) to west (backarc). The coda-wave energy is uniformly distributed in the forearc, whereas an exponential decrease with horizontal offset from the volcanic front is found in the backarc. The decay rate increases with increasing frequency.
We propose a diffusion–absorption model to give a physical insight into the observed regional variation in coda-wave energy. This model explains the observed characteristics successfully and predicts that the exponential variation of coda-wave energy in the backarc is a function of the diffusivity and the absorption coefficient. The magnitude of the intrinsic attenuation factor in the backarc is estimated at about Qi–1 = 0.02 at a frequency of 10 Hz by assuming a value of 0.01 km–1 for the scattering coefficient. This intrinsic attenuation factor is about twice as large as those reported from previous studies on the forearc.
Nous avons étudié la distribution spatiale de l'énergie de vague de S-coda dans Honshu du nord-est, Japon, où un avant volcanique fonctionne du nord au sud. Les séismogrammes d'un événement local avec une importance de 6.4 ont enregistré par bonjour le filet ont été analysés dans cette étude. Les amplitudes de moyenne carrée de vagues de coda à 82 stations séismiques ont été calculées pour des bandes avec des fréquences de 2-4, 4-8, 8-16, et 16-32 hertz. De ces mesures, on a observé une variation spatiale claire d'énergie de vague de coda à travers l'avant volcanique de l'est (arc antérieur) à l'ouest (arc arrière). L'énergie de vague de coda est uniformément distribuée dans l'arc antérieur, tandis qu'une diminution exponentielle avec l'excentrage horizontal de l'avant volcanique est trouvée de l'arc arrière. Les augmentations de taux d'affaiblissement avec l'augmentation de la fréquence. Nous proposons un modèle d'absorption de diffusion pour donner une perspicacité physique dans la variation régionale observée de l'énergie de vague de coda. Ce modèle explique les caractéristiques observées avec succès et prévoit que la variation exponentielle de l'énergie de vague de coda dans l'arc arrière est une fonction de la diffusivité et du coefficient d'absorption. L'importance du facteur intrinsèque d'atténuation dans l'arc arrière est estimée à environ Qi-1 = 0.02 à une fréquence de 10 hertz en assumant une valeur de 0.01 km-1 pour le coéfficient de dispersion. Ce facteur intrinsèque d'atténuation est environ deux fois plus grand que ceux rapportés des études précédentes sur l'arc antérieur.
|