[article]
Titre : |
Continuous protein recover with a liquid-solid circulating fluidized-bed ion exchanger |
Type de document : |
texte imprimé |
Auteurs : |
Lan, Qingdao, Auteur ; Margaritis, Argyrios ; Zhu, Jing-Xu ; Bassi, Amarjeet S., Auteur |
Année de publication : |
2007 |
Article en page(s) : |
252-261 p. |
Note générale : |
Génie Chimique |
Langues : |
Anglais (eng) |
Mots-clés : |
Lit fluidisé Echange ionique Protéines d'alimentation Adsorption Canalisation verticale Particules Colonnes Hydrodynamique Albumine de sérum boeuf |
Index. décimale : |
660 |
Résumé : |
A liquid-solid circulating fluidized-bed (LSCFB) ion-exchange system was developed for continuous protein recovery. It contains a downcomer for protein adsorption and a riser for protein desorption, with ion-exchange particles circulating continuously between the two columns. Effects of the operating conditions on the hydrodynamics and the continuous ion exchange of bovine serum albumin (BSA) in the system were investigated. Under typical operating conditions, up to 98% BSA was adsorbed in the downcomer (showing a very high efficiency of protein removal from the feed), and an overall protein recovery of up to 84% was obtained in the LSCFB system, indicating that the LSCFB system was a very promising strategy for the continuous recovery of proteins.
Un solide liquide circulant le système à lit fluidisé d'échange ionique (LSCFB) a été développé pour la récupération des protéines continue. Il contient vers le bas un arrivant pour l'adsorption de protéine et une canalisation verticale pour la désorption de protéine, avec des particules d'échange ionique circulant sans interruption entre les deux colonnes. Des effets des conditions de fonctionnement sur l'hydrodynamique et l'échange ionique continu de l'albumine de sérum de boeuf (BSA) dans le système ont été étudiés. Dans des conditions de fonctionnement typiques, jusqu'à 98% BSA a été adsorbé vers le bas (montrant un rendement très élevé d'enlèvement de protéine de l'alimentation), et une récupération des protéines globale jusqu'à de 84% a été obtenue en système de LSCFB, indiquant que le système de LSCFB était une stratégie très prometteuse pour le rétablissement continu des protéines.
|
DEWEY : |
660.627.3 |
ISSN : |
0001-1541 |
RAMEAU : |
Analyse de protèine |
En ligne : |
www.aiche.org, http://www3.interscience.wiley.com |
in Aiche journal > Vol. 48 N°2 (Fevrier 2002) . - 252-261 p.
[article] Continuous protein recover with a liquid-solid circulating fluidized-bed ion exchanger [texte imprimé] / Lan, Qingdao, Auteur ; Margaritis, Argyrios ; Zhu, Jing-Xu ; Bassi, Amarjeet S., Auteur . - 2007 . - 252-261 p. Génie Chimique Langues : Anglais ( eng) in Aiche journal > Vol. 48 N°2 (Fevrier 2002) . - 252-261 p.
Mots-clés : |
Lit fluidisé Echange ionique Protéines d'alimentation Adsorption Canalisation verticale Particules Colonnes Hydrodynamique Albumine de sérum boeuf |
Index. décimale : |
660 |
Résumé : |
A liquid-solid circulating fluidized-bed (LSCFB) ion-exchange system was developed for continuous protein recovery. It contains a downcomer for protein adsorption and a riser for protein desorption, with ion-exchange particles circulating continuously between the two columns. Effects of the operating conditions on the hydrodynamics and the continuous ion exchange of bovine serum albumin (BSA) in the system were investigated. Under typical operating conditions, up to 98% BSA was adsorbed in the downcomer (showing a very high efficiency of protein removal from the feed), and an overall protein recovery of up to 84% was obtained in the LSCFB system, indicating that the LSCFB system was a very promising strategy for the continuous recovery of proteins.
Un solide liquide circulant le système à lit fluidisé d'échange ionique (LSCFB) a été développé pour la récupération des protéines continue. Il contient vers le bas un arrivant pour l'adsorption de protéine et une canalisation verticale pour la désorption de protéine, avec des particules d'échange ionique circulant sans interruption entre les deux colonnes. Des effets des conditions de fonctionnement sur l'hydrodynamique et l'échange ionique continu de l'albumine de sérum de boeuf (BSA) dans le système ont été étudiés. Dans des conditions de fonctionnement typiques, jusqu'à 98% BSA a été adsorbé vers le bas (montrant un rendement très élevé d'enlèvement de protéine de l'alimentation), et une récupération des protéines globale jusqu'à de 84% a été obtenue en système de LSCFB, indiquant que le système de LSCFB était une stratégie très prometteuse pour le rétablissement continu des protéines.
|
DEWEY : |
660.627.3 |
ISSN : |
0001-1541 |
RAMEAU : |
Analyse de protèine |
En ligne : |
www.aiche.org, http://www3.interscience.wiley.com |
|