| Titre : | Dynamic response of retrofitted masonry walls for blast loading |
| Auteurs : | Girum S. Urgessa, Auteur ; Arup K. Maji, Auteur |
| Type de document : | Article : texte imprimé |
| Dans : | Journal of engineering mechanics (Vol. 136 N° 7, Juillet 2010) |
| Article en page(s) : | pp. 858-864 |
| Note générale : | Mécanique appliquée |
| Langues : | Anglais |
| Tags : | Blast loads Concrete Masonry Finite element method Fiber reinforced polymers Full-Scale tests Walls. |
| Résumé : | A full-scale blast test was conducted on eight masonry walls reinforced with two and four layers of carbon fibers and two types of polymer matrices. The walls were then subjected to a 0.45-kg pentolite booster suspended from the ceiling of a test structure. The pressure-time history caused by the blast and the resulting displacement response were measured during the test. This paper presents a summary of the test program and the corresponding results from a nonlinear single degree of freedom analysis. The results provide a basis for determining effective means of retrofitting existing masonry walls and designing new structures to withstand blast loads. The paper also outlines a fiber-reinforced polymer retrofit design procedure for walls subjected to blast loading. |
| DEWEY : | 620.1 |
| ISSN : | 0733-9399 |
| En ligne : | http://ascelibrary.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JENMDT000136000007000858000001&idtype=cvips&gifs=Yes&ref=no |