Les Inscriptions à la Bibliothèque sont ouvertes en
ligne via le site: https://biblio.enp.edu.dz
Les Réinscriptions se font à :
• La Bibliothèque Annexe pour les étudiants en
2ème Année CPST
• La Bibliothèque Centrale pour les étudiants en Spécialités
A partir de cette page vous pouvez :
Retourner au premier écran avec les recherches... |
Détail de l'auteur
Auteur Solanki, Jitendra
Documents disponibles écrits par cet auteur
Affiner la rechercheAn implementation of an adaptive control algorithm for a three-phase shunt active filter / Singh, Bhim in IEEE transactions on industrial electronics, Vol. 56 N° 8 (Août 2009)
[article]
in IEEE transactions on industrial electronics > Vol. 56 N° 8 (Août 2009) . - pp. 2811 - 2820
Titre : An implementation of an adaptive control algorithm for a three-phase shunt active filter Type de document : texte imprimé Auteurs : Singh, Bhim, Auteur ; Solanki, Jitendra, Auteur Article en page(s) : pp. 2811 - 2820 Note générale : Génie électrique Langues : Anglais (eng) Mots-clés : Adaptive linear element (Adaline) Harminics Reactive power Shunt active filter (SAF) Unbalance Index. décimale : 621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X Résumé : This paper deals with the hardware implementation of a shunt active filter (SAF) for compensation of reactive power, unbalanced loading, and harmonic currents. SAF is controlled using an adaptive-linear-element (Adaline)-based current estimator to maintain sinusoidal and unity-power-factor source currents. Three-phase load currents are sensed, and using least mean square (LMS) algorithm-based Adaline, online calculation of weights is performed and these weights are multiplied by the unit vector templates, which give the fundamental-frequency real component of load currents. The dc bus voltage of voltage source converter (VSC) working as a SAF is maintained at constant value using a proportional-integral controller. The switching of VSC is performed using hysteresis-based pulsewidth-modulation indirect-current-control scheme, which controls the source currents to follow the derived reference source currents. The practical implementation of the SAF is realized using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. The MATLAB-based simulation results and implementation results are presented to demonstrate the effectiveness of the SAF with Adaline-based control for load compensation. DEWEY : 621.38 ISSN : 0278-0046 En ligne : http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4776510 [article] An implementation of an adaptive control algorithm for a three-phase shunt active filter [texte imprimé] / Singh, Bhim, Auteur ; Solanki, Jitendra, Auteur . - pp. 2811 - 2820.
Génie électrique
Langues : Anglais (eng)
in IEEE transactions on industrial electronics > Vol. 56 N° 8 (Août 2009) . - pp. 2811 - 2820
Mots-clés : Adaptive linear element (Adaline) Harminics Reactive power Shunt active filter (SAF) Unbalance Index. décimale : 621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X Résumé : This paper deals with the hardware implementation of a shunt active filter (SAF) for compensation of reactive power, unbalanced loading, and harmonic currents. SAF is controlled using an adaptive-linear-element (Adaline)-based current estimator to maintain sinusoidal and unity-power-factor source currents. Three-phase load currents are sensed, and using least mean square (LMS) algorithm-based Adaline, online calculation of weights is performed and these weights are multiplied by the unit vector templates, which give the fundamental-frequency real component of load currents. The dc bus voltage of voltage source converter (VSC) working as a SAF is maintained at constant value using a proportional-integral controller. The switching of VSC is performed using hysteresis-based pulsewidth-modulation indirect-current-control scheme, which controls the source currents to follow the derived reference source currents. The practical implementation of the SAF is realized using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. The MATLAB-based simulation results and implementation results are presented to demonstrate the effectiveness of the SAF with Adaline-based control for load compensation. DEWEY : 621.38 ISSN : 0278-0046 En ligne : http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4776510 Neural Network-Based Selective Compensation of Current Quality Problems in Distribution System / Singh, Bhim in IEEE transactions on industrial electronics, Vol. 54 N°1 (Fevrier 2007)
[article]
in IEEE transactions on industrial electronics > Vol. 54 N°1 (Fevrier 2007) . - 53-60 p.
Titre : Neural Network-Based Selective Compensation of Current Quality Problems in Distribution System Titre original : Réseau Neurologique Basé sur la Compensation Sélective des Problèmes Courants de Qualité dans le Système de Distribution Type de document : texte imprimé Auteurs : Singh, Bhim, Auteur ; Verma, Vishal, Auteur ; Solanki, Jitendra Article en page(s) : 53-60 p. Note générale : Génie Electrique Langues : Anglais (eng) Mots-clés : Active power filter Adaline Decomposition Harmonic compensation Neural network Reactive power Unbalance.Filtre actif de puissance Adaline Décomposition Compensation harmonique Réseau neurologique Puissance réactive Désiquilibre. Index. décimale : 621 Ingénierie mécanique en général. Technologie nucléaire. Ingénierie électrique. Machinerie Résumé : Active power filters (APFs) have been used to compensate harmonics, reactive current, and negative sequence fundamental frequency current drawn by nonlinear loads. The control of APF is the core issue for their proper operation. The flexibility of selective compensation embedded in the control scheme makes APF versatile for compensation of reactive power, harmonic currents, and unbalance in source currents and their combinations, depending upon the limited rating of voltage source inverter employed as APF. The proposed scheme utilizes neural network-based decomposition of the load current into positive and negative sequence fundamental frequency component, reactive component and harmonic components. The adaline-based current decomposer estimates the reference currents through tracking of unit vectors together with tuning of the weights. The implementation of the control scheme facilitates selective compensation which respects the limited rating of the APF. The simulated results using developed MATLAB model are presented and are validated by experimental results to depict the effectiveness of the proposed control method of APF.
Des filtres actifs de puissance (APFs) ont été utilisés pour compenser les harmoniques, le courant réactif, et le courant négatif de fréquence fondamentale d'ordre dessiné par les charges non-linéaires. La commande de l'APF est la question de noyau pour leur opération appropriée. La flexibilité de la compensation sélective incluse dans l'arrangement de commande rend l'APF souple pour la compensation de la puissance réactive, des courants harmoniques, et du désiquilibre dans des courants de source et leurs combinaisons, dépendant de l'estimation limitée de l'inverseur de source de tension utilisé comme APF. L'arrangement proposé utilise la décomposition réseau-basée neurale du courant de charge dans le composant positif et négatif de fréquence fondamentale d'ordre, les composants composants et harmoniques réactifs. Le decomposer courant adaline-basé estime les courants de référence par le cheminement des vecteurs d'unité ainsi que l'accord des poids. L'exécution de l'arrangement de commande facilite la compensation sélective qui respecte l'estimation limitée de l'APF. Les résultats simulés employant le modèle développé de MATLAB sont présentés et sont validés par des résultats expérimentaux pour dépeindre l'efficacité de la méthode de contrôle proposée de l'APF.DEWEY : 621 ISSN : 0278-0046 En ligne : bsingh@ee.iitd.ac.in, ejitendra@yahoo.com, vishalvermal@hotmail.com [article] Neural Network-Based Selective Compensation of Current Quality Problems in Distribution System = Réseau Neurologique Basé sur la Compensation Sélective des Problèmes Courants de Qualité dans le Système de Distribution [texte imprimé] / Singh, Bhim, Auteur ; Verma, Vishal, Auteur ; Solanki, Jitendra . - 53-60 p.
Génie Electrique
Langues : Anglais (eng)
in IEEE transactions on industrial electronics > Vol. 54 N°1 (Fevrier 2007) . - 53-60 p.
Mots-clés : Active power filter Adaline Decomposition Harmonic compensation Neural network Reactive power Unbalance.Filtre actif de puissance Adaline Décomposition Compensation harmonique Réseau neurologique Puissance réactive Désiquilibre. Index. décimale : 621 Ingénierie mécanique en général. Technologie nucléaire. Ingénierie électrique. Machinerie Résumé : Active power filters (APFs) have been used to compensate harmonics, reactive current, and negative sequence fundamental frequency current drawn by nonlinear loads. The control of APF is the core issue for their proper operation. The flexibility of selective compensation embedded in the control scheme makes APF versatile for compensation of reactive power, harmonic currents, and unbalance in source currents and their combinations, depending upon the limited rating of voltage source inverter employed as APF. The proposed scheme utilizes neural network-based decomposition of the load current into positive and negative sequence fundamental frequency component, reactive component and harmonic components. The adaline-based current decomposer estimates the reference currents through tracking of unit vectors together with tuning of the weights. The implementation of the control scheme facilitates selective compensation which respects the limited rating of the APF. The simulated results using developed MATLAB model are presented and are validated by experimental results to depict the effectiveness of the proposed control method of APF.
Des filtres actifs de puissance (APFs) ont été utilisés pour compenser les harmoniques, le courant réactif, et le courant négatif de fréquence fondamentale d'ordre dessiné par les charges non-linéaires. La commande de l'APF est la question de noyau pour leur opération appropriée. La flexibilité de la compensation sélective incluse dans l'arrangement de commande rend l'APF souple pour la compensation de la puissance réactive, des courants harmoniques, et du désiquilibre dans des courants de source et leurs combinaisons, dépendant de l'estimation limitée de l'inverseur de source de tension utilisé comme APF. L'arrangement proposé utilise la décomposition réseau-basée neurale du courant de charge dans le composant positif et négatif de fréquence fondamentale d'ordre, les composants composants et harmoniques réactifs. Le decomposer courant adaline-basé estime les courants de référence par le cheminement des vecteurs d'unité ainsi que l'accord des poids. L'exécution de l'arrangement de commande facilite la compensation sélective qui respecte l'estimation limitée de l'APF. Les résultats simulés employant le modèle développé de MATLAB sont présentés et sont validés par des résultats expérimentaux pour dépeindre l'efficacité de la méthode de contrôle proposée de l'APF.DEWEY : 621 ISSN : 0278-0046 En ligne : bsingh@ee.iitd.ac.in, ejitendra@yahoo.com, vishalvermal@hotmail.com