Cell membrane electroporation. Part 3: the equipment / Rebersek, M. in IEEE electrical insulation magazine, Vol. 30 N° 3 (Mai-Juin 2014)
![]()
[article]
Titre : Cell membrane electroporation. Part 3: the equipment Type de document : texte imprimé Auteurs : Rebersek, M., Auteur ; Miklavcic, D., Auteur ; Bertacchini, C., Auteur Année de publication : 2015 Article en page(s) : pp. 8 - 18 Note générale : Génie électrique Langues : Français (fre) Mots-clés : Biomedical electrodes Biomembranes Cellular biophysics High-voltage techniques Molecular Pulse generators Résumé : As described in Part 1, a cell membrane can be made permeable to various molecules by carrying out a procedure called electroporation [1]. This procedure is being successfully used in biology, biotechnology, and medicine [2], [3]. It requires electroporators and electrodes. An electroporator generates short HV pulses of specific shape, amplitude, duration, number, and repetition frequency [4], and the pulses are applied to the target cells or load through the electrodes [5]. The energy delivered to the load is governed by the number of pulses and the pulse voltage, current, and duration. In biomedical applications that energy can be several joules; in biotechnology, where electroporation is used for treatment of agricultural products and water, it can be several kilojoules. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804737&filter%3DAND% [...]
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 8 - 18[article] Cell membrane electroporation. Part 3: the equipment [texte imprimé] / Rebersek, M., Auteur ; Miklavcic, D., Auteur ; Bertacchini, C., Auteur . - 2015 . - pp. 8 - 18.
Génie électrique
Langues : Français (fre)
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 8 - 18
Mots-clés : Biomedical electrodes Biomembranes Cellular biophysics High-voltage techniques Molecular Pulse generators Résumé : As described in Part 1, a cell membrane can be made permeable to various molecules by carrying out a procedure called electroporation [1]. This procedure is being successfully used in biology, biotechnology, and medicine [2], [3]. It requires electroporators and electrodes. An electroporator generates short HV pulses of specific shape, amplitude, duration, number, and repetition frequency [4], and the pulses are applied to the target cells or load through the electrodes [5]. The energy delivered to the load is governed by the number of pulses and the pulse voltage, current, and duration. In biomedical applications that energy can be several joules; in biotechnology, where electroporation is used for treatment of agricultural products and water, it can be several kilojoules. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804737&filter%3DAND% [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation / Lelekakis, N. in IEEE electrical insulation magazine, Vol. 30 N° 3 (Mai-Juin 2014)
![]()
[article]
Titre : The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation Type de document : texte imprimé Auteurs : Lelekakis, N., Auteur ; Wijaya, J., Auteur ; Martin, D., Auteur Année de publication : 2015 Article en page(s) : pp. 19 - 26 Note générale : Génie électrique Langues : Français (fre) Mots-clés : Ageing Polymerisation Power transformer insulation Résumé : In this article we explain how acids are formed in the oil and in paper insulation and their involvement in paper degradation. The acidity of the oil reached at the end of a number of paper-aging experiments is reported, and relationships between it and temperature, moisture, oxygen, degree of polymerization (DP), and aging time are presented. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804738&filter%3DAND% [...]
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 19 - 26[article] The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation [texte imprimé] / Lelekakis, N., Auteur ; Wijaya, J., Auteur ; Martin, D., Auteur . - 2015 . - pp. 19 - 26.
Génie électrique
Langues : Français (fre)
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 19 - 26
Mots-clés : Ageing Polymerisation Power transformer insulation Résumé : In this article we explain how acids are formed in the oil and in paper insulation and their involvement in paper degradation. The acidity of the oil reached at the end of a number of paper-aging experiments is reported, and relationships between it and temperature, moisture, oxygen, degree of polymerization (DP), and aging time are presented. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804738&filter%3DAND% [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire On-site testing and diagnosis of transmission power cables up to 230 kV using damped AC voltages / Gulski, E. in IEEE electrical insulation magazine, Vol. 30 N° 3 (Mai-Juin 2014)
![]()
[article]
Titre : On-site testing and diagnosis of transmission power cables up to 230 kV using damped AC voltages Type de document : texte imprimé Auteurs : Gulski, E., Auteur ; Rakowska, A., Auteur ; Siodla, K., Auteur Année de publication : 2015 Article en page(s) : pp. 27 - 38 Note générale : Génie électrique Langues : Français (fre) Mots-clés : Damping Power cables Transmission networks Résumé : This article presents an overview of on-site testing and diagnosis of new and service-aged transmission HV power cables up to 230 kV using damped AC voltages. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804739&filter%3DAND% [...]
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 27 - 38[article] On-site testing and diagnosis of transmission power cables up to 230 kV using damped AC voltages [texte imprimé] / Gulski, E., Auteur ; Rakowska, A., Auteur ; Siodla, K., Auteur . - 2015 . - pp. 27 - 38.
Génie électrique
Langues : Français (fre)
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 27 - 38
Mots-clés : Damping Power cables Transmission networks Résumé : This article presents an overview of on-site testing and diagnosis of new and service-aged transmission HV power cables up to 230 kV using damped AC voltages. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804739&filter%3DAND% [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire A review of dissolved gas analysis measurement and interpretation techniques / Bakar, N. A. in IEEE electrical insulation magazine, Vol. 30 N° 3 (Mai-Juin 2014)
![]()
[article]
Titre : A review of dissolved gas analysis measurement and interpretation techniques Type de document : texte imprimé Auteurs : Bakar, N. A., Auteur ; Abu-Siada, A., Auteur ; Islam, S., Auteur Année de publication : 2015 Article en page(s) : pp. 39 - 49 Note générale : Génie électrique Langues : Français (fre) Mots-clés : Paper Power transformer insulation Transformer oil Résumé : Dissolved gas analysis (DGA) is used to assess the condition of power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. DGA has gained worldwide acceptance as a method for the detection of incipient faults in transformers. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804740&filter%3DAND% [...]
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 39 - 49[article] A review of dissolved gas analysis measurement and interpretation techniques [texte imprimé] / Bakar, N. A., Auteur ; Abu-Siada, A., Auteur ; Islam, S., Auteur . - 2015 . - pp. 39 - 49.
Génie électrique
Langues : Français (fre)
in IEEE electrical insulation magazine > Vol. 30 N° 3 (Mai-Juin 2014) . - pp. 39 - 49
Mots-clés : Paper Power transformer insulation Transformer oil Résumé : Dissolved gas analysis (DGA) is used to assess the condition of power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. DGA has gained worldwide acceptance as a method for the detection of incipient faults in transformers. En ligne : http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6804740&filter%3DAND% [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire