This study details a new moment connection that overcomes difficulties in achieving field-weld quality and eliminates steel beam buckling encountered in steel moment connections. This study presents cyclic test and finite element analysis results of full-scale subassemblies using steel reduced flange plates (RFPs) to connect steel beam flanges and the column without any other direct connection. Since the RFP connection is designed as strong column-strong beam-weak RFPs, the RFP functions as a structural fuse that eliminates weld fractures and beam buckling. Test and analytical results show that (1) the connections transferred the entire beam flexural strength to the column and reached an interstorey drift of 4% with minor strength degradation, (2) failure of the connections was owing to buckling or fracturing of the RFP and not of the beam, and (3) the RFP connection subassembly, modelled using the nonlinear finite element computer program ABAQUS, exhibited hysteretic behaviour similar to that of the flange plate (FP) moment connection subassembly. The inelastic buckling force of the RFP was also evaluated by nonlinear regression analyses performed on a nonlinear model that relates buckling force to RFP geometries.
Cette étude détaille une nouvelle heure de connexion qui permet de surmonter les difficultés dans la réalisation de terrain qualité des soudures et élimine poutre d'acier flambement rencontrés en acier instant connexions. Cette étude présente essai cyclique et de l'analyse par éléments finis résultats de la pleine échelle, les sous-ensembles en utilisant les plaques d'acier de boudin réduit (DP) pour connecter les brides poutre d'acier et de la colonne sans autre connexion directe. Depuis la DP connexion est conçu comme une forte colonne forte de faisceau-faible DP, la DP fonctionne comme un fusible structurelles qui élimine la soudure des fractures et faisceau gauchissement. Test et résultats d'analyse montrent que (1) les connexions transféré la totalité du faisceau de résistance en flexion de la colonne et a atteint un interstorey dérive de 4% avec une dégradation de leur résistance mineures, (2) l'échec de la connexion était dû à l'attachement ou de la fracturation et de la DP Pas de la poutre, et (3) la DP égard des sous-ensembles, sur le modèle non linéaire utilisant le programme d'ordinateur d'éléments finis ABAQUS, hystérésis présentaient un comportement similaire à celui de la bride de plaque (FO) instant égard des sous-ensembles. Le flambement inélastique vigueur de la demande de propositions a également été évaluées par des analyses de régression non linéaire réalisé à partir d'un modèle non linéaire qui se rapporte à la force de flambement DP géométries. |
DEWEY : |
551.2 |
ISSN : |
0098-8847 |
RAMEAU : |
Génie parasismique-- Acier |
En ligne : |
http://www3.interscience.wiley.com/cgi-bin/abstract/114279677/ABSTRACT?CRETRY=1& [...] |
in Earthquake engineering structural dynamics > Vol. 36 N°14 (Novembre 2007) . - 2083-2097 p.
[article] Performance evaluation of steel reduced flange plate moment connections [texte imprimé] / Chung-Che Chou, Auteur ; Chia-Ching Wu, Auteur . - 2007 . - 2083-2097 p. Génie Civil Langues : Anglais ( eng) in Earthquake engineering structural dynamics > Vol. 36 N°14 (Novembre 2007) . - 2083-2097 p.
Mots-clés : |
reduced flange plate moment connection cyclic test finite element analysis nonlinear regression bucklingBride Essai cyclique Analyse par éléments finis de régression non linéaire Flambement |
Résumé : |
This study details a new moment connection that overcomes difficulties in achieving field-weld quality and eliminates steel beam buckling encountered in steel moment connections. This study presents cyclic test and finite element analysis results of full-scale subassemblies using steel reduced flange plates (RFPs) to connect steel beam flanges and the column without any other direct connection. Since the RFP connection is designed as strong column-strong beam-weak RFPs, the RFP functions as a structural fuse that eliminates weld fractures and beam buckling. Test and analytical results show that (1) the connections transferred the entire beam flexural strength to the column and reached an interstorey drift of 4% with minor strength degradation, (2) failure of the connections was owing to buckling or fracturing of the RFP and not of the beam, and (3) the RFP connection subassembly, modelled using the nonlinear finite element computer program ABAQUS, exhibited hysteretic behaviour similar to that of the flange plate (FP) moment connection subassembly. The inelastic buckling force of the RFP was also evaluated by nonlinear regression analyses performed on a nonlinear model that relates buckling force to RFP geometries.
Cette étude détaille une nouvelle heure de connexion qui permet de surmonter les difficultés dans la réalisation de terrain qualité des soudures et élimine poutre d'acier flambement rencontrés en acier instant connexions. Cette étude présente essai cyclique et de l'analyse par éléments finis résultats de la pleine échelle, les sous-ensembles en utilisant les plaques d'acier de boudin réduit (DP) pour connecter les brides poutre d'acier et de la colonne sans autre connexion directe. Depuis la DP connexion est conçu comme une forte colonne forte de faisceau-faible DP, la DP fonctionne comme un fusible structurelles qui élimine la soudure des fractures et faisceau gauchissement. Test et résultats d'analyse montrent que (1) les connexions transféré la totalité du faisceau de résistance en flexion de la colonne et a atteint un interstorey dérive de 4% avec une dégradation de leur résistance mineures, (2) l'échec de la connexion était dû à l'attachement ou de la fracturation et de la DP Pas de la poutre, et (3) la DP égard des sous-ensembles, sur le modèle non linéaire utilisant le programme d'ordinateur d'éléments finis ABAQUS, hystérésis présentaient un comportement similaire à celui de la bride de plaque (FO) instant égard des sous-ensembles. Le flambement inélastique vigueur de la demande de propositions a également été évaluées par des analyses de régression non linéaire réalisé à partir d'un modèle non linéaire qui se rapporte à la force de flambement DP géométries. |
DEWEY : |
551.2 |
ISSN : |
0098-8847 |
RAMEAU : |
Génie parasismique-- Acier |
En ligne : |
http://www3.interscience.wiley.com/cgi-bin/abstract/114279677/ABSTRACT?CRETRY=1& [...] |
|