Les Inscriptions à la Bibliothèque sont ouvertes en
ligne via le site: https://biblio.enp.edu.dz
Les Réinscriptions se font à :
• La Bibliothèque Annexe pour les étudiants en
2ème Année CPST
• La Bibliothèque Centrale pour les étudiants en Spécialités
A partir de cette page vous pouvez :
Retourner au premier écran avec les recherches... |
Earthquake engineering structural dynamics / Chopra, Anil K. . Vol. 35 N° 13Earthquake Engineering Structural DynamicsMention de date : Novembre 2006 Paru le : 12/12/2006 |
Dépouillements
Ajouter le résultat dans votre panierRC pile-soil interaction analysis using a 3D-finite element method with fibre theory-based beam elements / Maki, Takeshi in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1587 - 1607 p.
Titre : RC pile-soil interaction analysis using a 3D-finite element method with fibre theory-based beam elements Type de document : texte imprimé Auteurs : Maki, Takeshi, Auteur ; Mutsuyoshi, Hiroshi, Auteur ; Maekawa, Koichi, Auteur Article en page(s) : 1587 - 1607 p. Note générale : Génie civil Langues : Anglais (eng) Mots-clés : RC pile Subgrade soil reaction 3D-FEM analysis Fibre model Beam element Interface between pile and soil Pile de RC Réaction de sol de sous-grade Analyse de 3D-FEM Modèle de fibre Elément de faisceau Interface entre la pile et le sol Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : To evaluate the overall response of a structural system including its foundation and surrounding soil, an equivalent finite element model with reduced degrees of freedom using fibre theory-based beam element was proposed. The proposed model was based on investigations of the subgrade soil reaction of a single-layer model, and was verified for the cyclic behaviour of a laterally loaded single RC pile in terms of the load-displacement relationship, pile deformation, and soil pressures on the pile surface. Also investigated was the effect of the interfacial element between pile and soil on the behaviour of the laterally loaded pile.
Pour évaluer la réponse globale d'un système structural comprenant sa base et sol environnant, on a proposé un modèle d'élément fini équivalent avec des degrés de liberté réduits employant l'élément de théorie de faisceau basé par fibre. Le modèle proposé a été basé sur des investigations sur la réaction de sol de sous-grade d'un modèle à une seule couche, et a été vérifié pour assurer le comportement cyclique d'une pile simple latéralement chargée de RC en termes de rapport de charge-déplacement, déformation de pile, et les pressions de sol sur la pile. En outre on a étudié l'effet de l'élément dièdre entre la pile et le sol sur le comportement de la pile latéralement chargée.ISSN : 0098-8847 RAMEAU : Faisceau -- Intéraction -- Sol -- Pile En ligne : ://www3.interscience.wiley.com/cgi-bin/abstract/112635322/ABSTRACT [article] RC pile-soil interaction analysis using a 3D-finite element method with fibre theory-based beam elements [texte imprimé] / Maki, Takeshi, Auteur ; Mutsuyoshi, Hiroshi, Auteur ; Maekawa, Koichi, Auteur . - 1587 - 1607 p.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1587 - 1607 p.
Mots-clés : RC pile Subgrade soil reaction 3D-FEM analysis Fibre model Beam element Interface between pile and soil Pile de RC Réaction de sol de sous-grade Analyse de 3D-FEM Modèle de fibre Elément de faisceau Interface entre la pile et le sol Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : To evaluate the overall response of a structural system including its foundation and surrounding soil, an equivalent finite element model with reduced degrees of freedom using fibre theory-based beam element was proposed. The proposed model was based on investigations of the subgrade soil reaction of a single-layer model, and was verified for the cyclic behaviour of a laterally loaded single RC pile in terms of the load-displacement relationship, pile deformation, and soil pressures on the pile surface. Also investigated was the effect of the interfacial element between pile and soil on the behaviour of the laterally loaded pile.
Pour évaluer la réponse globale d'un système structural comprenant sa base et sol environnant, on a proposé un modèle d'élément fini équivalent avec des degrés de liberté réduits employant l'élément de théorie de faisceau basé par fibre. Le modèle proposé a été basé sur des investigations sur la réaction de sol de sous-grade d'un modèle à une seule couche, et a été vérifié pour assurer le comportement cyclique d'une pile simple latéralement chargée de RC en termes de rapport de charge-déplacement, déformation de pile, et les pressions de sol sur la pile. En outre on a étudié l'effet de l'élément dièdre entre la pile et le sol sur le comportement de la pile latéralement chargée.ISSN : 0098-8847 RAMEAU : Faisceau -- Intéraction -- Sol -- Pile En ligne : ://www3.interscience.wiley.com/cgi-bin/abstract/112635322/ABSTRACT Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessment / García, Jorge Ruiz in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1609 - 1629 p.
Titre : Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessment Type de document : texte imprimé Auteurs : García, Jorge Ruiz, Auteur ; Miranda, Eduardo, Auteur Article en page(s) : 1609 - 1629 p. Note générale : Génie civil Langues : Anglais (eng) Mots-clés : Residual drift demands Assessment of existing structures Inelastic intensity measure Probabilistic seismic demand analysis Demandes résiduelles de dérive Evaluation des structures existantes Mesure non élastique d'intensité Analyse de la demande séismique probabiliste Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : This paper summarizes results of a comprehensive analytical study aimed at evaluating the amplitude and heightwise distribution of residual drift demands in multi-storey moment-resisting frames after earthquake excitation. For that purpose, a family of 12 one-bay two-dimensional generic frame models was subjected to an ensemble of 40 ground motions scaled to different intensities. In this investigation, an inelastic ground motion intensity measure was employed to scale each record, which allowed reducing the record-to-record variability in the estimation of residual drift demands. The results were statistically processed in order to evaluate the influence of ground motion intensity, number of stories, period of vibration, frame mechanism, system overstrength, and hysteretic behaviour on central tendency of residual drift demands. In addition, a special emphasis was given to evaluate the uncertainty in the estimation of residual drift demands. Results of incremental dynamic analyses indicate that the amplitude and heightwise distribution of residual drift demands strongly depends on the frame mechanism, the heightwise system structural overstrength and the component hysteretic behaviour. An important conclusion for performance-based assessment is that the evaluation of residual drift demands involves significantly larger levels of uncertainty (i.e. record-to-record variability) than that of maximum drift demands, which suggests that this variability and corresponding uncertainty should be explicitly taken into account when estimating residual drift demands during performance-based seismic assessment of frame buildings.
Cet article récapitule des résultats d'une étude analytique complète visée évaluant l'amplitude et la distribution de heightwise de la dérive résiduelle exige dans les armatures de résistance de plusieurs étages après l'excitation de tremblement de terre. Dans ce but, une famille de 12 modèles génériques bidimensionnels d'armature d'un-compartiment a été soumise à un ensemble de 40 mouvements au sol mesurés à différentes intensités. Dans cette recherche, une mesure au sol non élastique d'intensité de mouvement a été utilisée de mesurer chaque disque, qui a permis la réduction à-enregistre la variabilité dans l'évaluation des demandes résiduelles de dérive. Les résultats ont été statistiquement traités afin d'évaluer l'influence de l'intensité au sol de mouvement, le nombre d'histoires, période de vibration, mécanisme d'armature, au-dessus-force de système, et le comportement par hystérésis sur la tendance centrale de la dérive résiduelle exige. En outre, une considération particulière a été donnée pour évaluer l'incertitude dans l'évaluation des demandes résiduelles de dérive. Les résultats des analyses dynamiques par accroissement indiquent que la distribution d'amplitude de taille sage des demandes résiduelles de dérive dépend fortement du mécanisme d'armature, de l'overstrength structural de système de taille sage et du comportement par hystérésis composant. Une conclusion importante pour l'évaluation exécution-basée est que l'évaluation des demandes résiduelles de dérive implique des niveaux sensiblement plus grands de l'incertitude (c.-à-d. enregistrer-à-enregistrez la variabilité) que cela des demandes maximum de dérive, qui suggère que ces variabilité et incertitude correspondante devraient être explicitement prises en considération en estimant la dérive résiduelle exige pendant l'évaluation séismique exécution-basée des bâtiments d'armature.ISSN : 0098-8847 RAMEAU : Analyse dynamique -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue?CRETRY=1&SRETRY=0 [article] Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessment [texte imprimé] / García, Jorge Ruiz, Auteur ; Miranda, Eduardo, Auteur . - 1609 - 1629 p.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1609 - 1629 p.
Mots-clés : Residual drift demands Assessment of existing structures Inelastic intensity measure Probabilistic seismic demand analysis Demandes résiduelles de dérive Evaluation des structures existantes Mesure non élastique d'intensité Analyse de la demande séismique probabiliste Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : This paper summarizes results of a comprehensive analytical study aimed at evaluating the amplitude and heightwise distribution of residual drift demands in multi-storey moment-resisting frames after earthquake excitation. For that purpose, a family of 12 one-bay two-dimensional generic frame models was subjected to an ensemble of 40 ground motions scaled to different intensities. In this investigation, an inelastic ground motion intensity measure was employed to scale each record, which allowed reducing the record-to-record variability in the estimation of residual drift demands. The results were statistically processed in order to evaluate the influence of ground motion intensity, number of stories, period of vibration, frame mechanism, system overstrength, and hysteretic behaviour on central tendency of residual drift demands. In addition, a special emphasis was given to evaluate the uncertainty in the estimation of residual drift demands. Results of incremental dynamic analyses indicate that the amplitude and heightwise distribution of residual drift demands strongly depends on the frame mechanism, the heightwise system structural overstrength and the component hysteretic behaviour. An important conclusion for performance-based assessment is that the evaluation of residual drift demands involves significantly larger levels of uncertainty (i.e. record-to-record variability) than that of maximum drift demands, which suggests that this variability and corresponding uncertainty should be explicitly taken into account when estimating residual drift demands during performance-based seismic assessment of frame buildings.
Cet article récapitule des résultats d'une étude analytique complète visée évaluant l'amplitude et la distribution de heightwise de la dérive résiduelle exige dans les armatures de résistance de plusieurs étages après l'excitation de tremblement de terre. Dans ce but, une famille de 12 modèles génériques bidimensionnels d'armature d'un-compartiment a été soumise à un ensemble de 40 mouvements au sol mesurés à différentes intensités. Dans cette recherche, une mesure au sol non élastique d'intensité de mouvement a été utilisée de mesurer chaque disque, qui a permis la réduction à-enregistre la variabilité dans l'évaluation des demandes résiduelles de dérive. Les résultats ont été statistiquement traités afin d'évaluer l'influence de l'intensité au sol de mouvement, le nombre d'histoires, période de vibration, mécanisme d'armature, au-dessus-force de système, et le comportement par hystérésis sur la tendance centrale de la dérive résiduelle exige. En outre, une considération particulière a été donnée pour évaluer l'incertitude dans l'évaluation des demandes résiduelles de dérive. Les résultats des analyses dynamiques par accroissement indiquent que la distribution d'amplitude de taille sage des demandes résiduelles de dérive dépend fortement du mécanisme d'armature, de l'overstrength structural de système de taille sage et du comportement par hystérésis composant. Une conclusion importante pour l'évaluation exécution-basée est que l'évaluation des demandes résiduelles de dérive implique des niveaux sensiblement plus grands de l'incertitude (c.-à-d. enregistrer-à-enregistrez la variabilité) que cela des demandes maximum de dérive, qui suggère que ces variabilité et incertitude correspondante devraient être explicitement prises en considération en estimant la dérive résiduelle exige pendant l'évaluation séismique exécution-basée des bâtiments d'armature.ISSN : 0098-8847 RAMEAU : Analyse dynamique -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue?CRETRY=1&SRETRY=0 Bench-shelf system dynamic characteristics and their effects on equipment and contents / Hutchinson, Tara C. in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1631 - 1651 p.
Titre : Bench-shelf system dynamic characteristics and their effects on equipment and contents Type de document : texte imprimé Auteurs : Hutchinson, Tara C., Auteur ; Chaudhuri, Samit Ray, Auteur Article en page(s) : 1631 - 1651 p. Note générale : Génie civil Langues : Anglais (eng) Mots-clés : Shake table testing Nonstructural components Dynamic characterization Furniture response Acceleration amplification Essai de table de secousse Composants nonstructural Caractérisation dynamique Réponse de meubles Amplification d'accélération Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : Economic losses during past earthquakes are strongly associated with damage and failure to nonstructural equipment and contents. Among the vast types of nonstructural elements, one important category, is scientific equipment in biological or chemical laboratories. These equipment are often mounted on heavy ceramic bench-tops of bench-shelf systems, which in turn may amplify the dynamic motions imposed. To investigate the seismic response of these types of systems, a series of shake table and field experiments were conducted considering different representative bench and shelf-mounted equipment and contents.
Results from shake table experiments indicate that these equipment are generally sliding-dominated. In addition, the bench-shelf system is observed to be very stiff and when lightly loaded, has a fundamental frequency between 10 and 16 Hz. An approximate 50% reduction in the first and second fundamental frequencies is observed considering practical loading conditions. Insight into a broader range of system response is provided by conducting eigenvalue and time history analyses. Non-linear regression through the numerical data indicate acceleration amplification ratios range from 2.6 to 1.4 and from 4.3 to 1.6, for fixed-fixed and pinned-pinned conditions, respectively. Both the experimental and numerical results support the importance of determining the potential dynamic amplification of motion in the context of accurately determining the maximum sliding displacement of support equipment and contents.
Des pertes économiques pendant des tremblements de terre passés sont fortement associées aux dommages et à l'échec à l'équipement et au contenu non structural. Parmi les vastes types d'éléments non structural, une catégorie importante, est équipement scientifique dans les laboratoires biologiques ou chimiques. Ces l'équipement sont souvent montés sur mettre hors jeu-tops en céramique lourd des systèmes de mettre hors jeu-shelf, qui alternativement peuvent amplifier les mouvements dynamiques imposés. Pour étudier la réponse séismique de ces types de systèmes, une série de table de secousse et des expériences sur le terrain ont été conduites considérant le représentant différent mettent hors jeu et étagère-ont monté l'équipement et le contenu. Les résultats des expériences de table de secousse indiquent que ces équipements glisser-sont généralement dominés. En outre, le système de mettre hors jeu-shelf est observé pour être très raide et une fois légèrement chargé, a une fréquence fondamentale entre 10 et 16 hertz. On observe une réduction approximative de 50% des premières et deuxièmes fréquences fondamentales considérer des conditions de charge pratiques. L'aperçu d'une plus large gamme de réaction de système est fourni en conduisant des analyses d'histoire de valeur propre et de temps. La régression non linéaire par les données numériques indiquent que des rapports d'amplification d'accélération s'étendent de 2.6 à 1.4 et de 4.3 à 1.6, parce que de conditions fixe-fixes et goupiller-goupillées, respectivement. Les résultats expérimentaux et numériques soutiennent l'importance de déterminer l'amplification dynamique potentiel du mouvement dans le contexte de déterminer exactement le déplacement coulissant de maximum de l'équipement et du contenu de soutien.ISSN : 0098-8847 RAMEAU : Secousse En ligne : http://www3.interscience.wiley.com/journal/117869386/issue [article] Bench-shelf system dynamic characteristics and their effects on equipment and contents [texte imprimé] / Hutchinson, Tara C., Auteur ; Chaudhuri, Samit Ray, Auteur . - 1631 - 1651 p.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1631 - 1651 p.
Mots-clés : Shake table testing Nonstructural components Dynamic characterization Furniture response Acceleration amplification Essai de table de secousse Composants nonstructural Caractérisation dynamique Réponse de meubles Amplification d'accélération Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : Economic losses during past earthquakes are strongly associated with damage and failure to nonstructural equipment and contents. Among the vast types of nonstructural elements, one important category, is scientific equipment in biological or chemical laboratories. These equipment are often mounted on heavy ceramic bench-tops of bench-shelf systems, which in turn may amplify the dynamic motions imposed. To investigate the seismic response of these types of systems, a series of shake table and field experiments were conducted considering different representative bench and shelf-mounted equipment and contents.
Results from shake table experiments indicate that these equipment are generally sliding-dominated. In addition, the bench-shelf system is observed to be very stiff and when lightly loaded, has a fundamental frequency between 10 and 16 Hz. An approximate 50% reduction in the first and second fundamental frequencies is observed considering practical loading conditions. Insight into a broader range of system response is provided by conducting eigenvalue and time history analyses. Non-linear regression through the numerical data indicate acceleration amplification ratios range from 2.6 to 1.4 and from 4.3 to 1.6, for fixed-fixed and pinned-pinned conditions, respectively. Both the experimental and numerical results support the importance of determining the potential dynamic amplification of motion in the context of accurately determining the maximum sliding displacement of support equipment and contents.
Des pertes économiques pendant des tremblements de terre passés sont fortement associées aux dommages et à l'échec à l'équipement et au contenu non structural. Parmi les vastes types d'éléments non structural, une catégorie importante, est équipement scientifique dans les laboratoires biologiques ou chimiques. Ces l'équipement sont souvent montés sur mettre hors jeu-tops en céramique lourd des systèmes de mettre hors jeu-shelf, qui alternativement peuvent amplifier les mouvements dynamiques imposés. Pour étudier la réponse séismique de ces types de systèmes, une série de table de secousse et des expériences sur le terrain ont été conduites considérant le représentant différent mettent hors jeu et étagère-ont monté l'équipement et le contenu. Les résultats des expériences de table de secousse indiquent que ces équipements glisser-sont généralement dominés. En outre, le système de mettre hors jeu-shelf est observé pour être très raide et une fois légèrement chargé, a une fréquence fondamentale entre 10 et 16 hertz. On observe une réduction approximative de 50% des premières et deuxièmes fréquences fondamentales considérer des conditions de charge pratiques. L'aperçu d'une plus large gamme de réaction de système est fourni en conduisant des analyses d'histoire de valeur propre et de temps. La régression non linéaire par les données numériques indiquent que des rapports d'amplification d'accélération s'étendent de 2.6 à 1.4 et de 4.3 à 1.6, parce que de conditions fixe-fixes et goupiller-goupillées, respectivement. Les résultats expérimentaux et numériques soutiennent l'importance de déterminer l'amplification dynamique potentiel du mouvement dans le contexte de déterminer exactement le déplacement coulissant de maximum de l'équipement et du contenu de soutien.ISSN : 0098-8847 RAMEAU : Secousse En ligne : http://www3.interscience.wiley.com/journal/117869386/issue Component and shaking table tests for full-scale multiple friction pendulum system / Tsai, C. S. in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1653 - 1675 p.
Titre : Component and shaking table tests for full-scale multiple friction pendulum system Type de document : texte imprimé Auteurs : Tsai, C. S., Auteur ; Chen, Bo-Jen, Auteur ; Chiang, Tsu-Cheng, Auteur ; Chen, Wen-Shin, Auteur Article en page(s) : 1653 - 1675 p. Note générale : Génie civil Langues : Anglais (eng) Mots-clés : Base isolation Friction pendulum Shaking table tests Component tests Isolement bas Pendule de frottement Secousse des essais de table Essais composants Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : The use of base isolation in developed countries including the U.S. and Japan has already been recognized as a very effective method for upgrading the seismic resistance of structures. In this study, an advanced base-isolation system called the multiple friction pendulum system (MFPS) is investigated to understand its performance on seismic mitigation through full-scale component and shaking table tests. The component tests of the advanced Teflon composite coated on the sliding surface show that the friction coefficient of the lubricant material is a function of the sliding velocity in the range of 0.03-0.12. The experimental results also indicate that there were no signs of degradation of the sliding interface observed after 2000 cycles of sliding displacements. A full-scale MFPS isolator under a vertically compressive load of 8830 KN (900 tf) and horizontally cyclic displacements was tested in order to assess the feasibility of the MFPS isolator for its practical use. After 248 cycles of horizontal displacement reversals, the behaviour of the base isolator was almost identical to its behaviour during the first few cycles. The experimental results of the shaking table tests of a full-scale steel structure isolated with MFPS isolators show that the MFPS device can isolate seismic transmitted energy effectively under soft-soil-deposit site earthquakes with long predominant periods as well as strong ground motions with short predominant periods. These test results demonstrate that the MFPS isolator possesses excellent durability and outstanding earthquake-proof capability. Furthermore, the numerical results show that the mathematical model proposed in this study can well predict the seismic responses of a structure isolated with MFPS isolators.
L'utilisation de l'isolement bas dans les pays développés comprenant les ETATS-UNIS et le Japon a été déjà identifiée comme méthode très efficace pour améliorer la résistance séismique des structures. Dans cette étude, un système avançé d'base-isolement appelé le système multiple de pendule de frottement (MFPS) est étudié pour comprendre son exécution sur la réduction séismique le composant complet et en secouant des essais de table. Les essais composants de l'enduit composé de teflon avançé sur l'exposition de surface de glissement que le coefficient de frottement du matériel de lubrifiant est une fonction de la vitesse coulissante dans la gamme de 0.03-0.12. Les résultats expérimentaux indiquent également qu'il n'y avait aucun signe de la dégradation de l'interface coulissante observée après 2000 cycles de déplacements coulissants. Un isolant complet de MFPS sous une charge verticalement compressive de 8830 KN (900 tf) et horizontalement des déplacements cycliques a été examiné afin d'évaluer la praticabilité de l'isolant de MFPS pour son usage pratique. Après 248 cycles d'inversions horizontales de déplacement, le comportement de l'isolant bas était presque identique à son comportement pendant les cycles premiers. Les résultats expérimentaux des essais de secousse de table d'une structure métallique complète d'isolement avec des isolants de MFPS prouvent que le dispositif de MFPS peut isoler l'énergie transmise séismique efficacement sous doux-sol-déposent des tremblements de terre d'emplacement avec de longues périodes prédominantes aussi bien que des mouvements au sol forts avec des périodes prédominantes courtes. Ces résultats d'essai démontrent que l'isolant de MFPS possède l'excellente longévité et les possibilités exceptionnelles de tremblement de terre-preuve. En outre, les résultats numériques prouvent que le modèle mathématique proposé dans cette étude peut jaillir prévoient les réponses séismiques d'une structure d'isolement avec des isolants de MFPS.ISSN : 0098-8847 RAMEAU : Frottement en visco-élasticité -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue [article] Component and shaking table tests for full-scale multiple friction pendulum system [texte imprimé] / Tsai, C. S., Auteur ; Chen, Bo-Jen, Auteur ; Chiang, Tsu-Cheng, Auteur ; Chen, Wen-Shin, Auteur . - 1653 - 1675 p.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1653 - 1675 p.
Mots-clés : Base isolation Friction pendulum Shaking table tests Component tests Isolement bas Pendule de frottement Secousse des essais de table Essais composants Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : The use of base isolation in developed countries including the U.S. and Japan has already been recognized as a very effective method for upgrading the seismic resistance of structures. In this study, an advanced base-isolation system called the multiple friction pendulum system (MFPS) is investigated to understand its performance on seismic mitigation through full-scale component and shaking table tests. The component tests of the advanced Teflon composite coated on the sliding surface show that the friction coefficient of the lubricant material is a function of the sliding velocity in the range of 0.03-0.12. The experimental results also indicate that there were no signs of degradation of the sliding interface observed after 2000 cycles of sliding displacements. A full-scale MFPS isolator under a vertically compressive load of 8830 KN (900 tf) and horizontally cyclic displacements was tested in order to assess the feasibility of the MFPS isolator for its practical use. After 248 cycles of horizontal displacement reversals, the behaviour of the base isolator was almost identical to its behaviour during the first few cycles. The experimental results of the shaking table tests of a full-scale steel structure isolated with MFPS isolators show that the MFPS device can isolate seismic transmitted energy effectively under soft-soil-deposit site earthquakes with long predominant periods as well as strong ground motions with short predominant periods. These test results demonstrate that the MFPS isolator possesses excellent durability and outstanding earthquake-proof capability. Furthermore, the numerical results show that the mathematical model proposed in this study can well predict the seismic responses of a structure isolated with MFPS isolators.
L'utilisation de l'isolement bas dans les pays développés comprenant les ETATS-UNIS et le Japon a été déjà identifiée comme méthode très efficace pour améliorer la résistance séismique des structures. Dans cette étude, un système avançé d'base-isolement appelé le système multiple de pendule de frottement (MFPS) est étudié pour comprendre son exécution sur la réduction séismique le composant complet et en secouant des essais de table. Les essais composants de l'enduit composé de teflon avançé sur l'exposition de surface de glissement que le coefficient de frottement du matériel de lubrifiant est une fonction de la vitesse coulissante dans la gamme de 0.03-0.12. Les résultats expérimentaux indiquent également qu'il n'y avait aucun signe de la dégradation de l'interface coulissante observée après 2000 cycles de déplacements coulissants. Un isolant complet de MFPS sous une charge verticalement compressive de 8830 KN (900 tf) et horizontalement des déplacements cycliques a été examiné afin d'évaluer la praticabilité de l'isolant de MFPS pour son usage pratique. Après 248 cycles d'inversions horizontales de déplacement, le comportement de l'isolant bas était presque identique à son comportement pendant les cycles premiers. Les résultats expérimentaux des essais de secousse de table d'une structure métallique complète d'isolement avec des isolants de MFPS prouvent que le dispositif de MFPS peut isoler l'énergie transmise séismique efficacement sous doux-sol-déposent des tremblements de terre d'emplacement avec de longues périodes prédominantes aussi bien que des mouvements au sol forts avec des périodes prédominantes courtes. Ces résultats d'essai démontrent que l'isolant de MFPS possède l'excellente longévité et les possibilités exceptionnelles de tremblement de terre-preuve. En outre, les résultats numériques prouvent que le modèle mathématique proposé dans cette étude peut jaillir prévoient les réponses séismiques d'une structure d'isolement avec des isolants de MFPS.ISSN : 0098-8847 RAMEAU : Frottement en visco-élasticité -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue Merging energy-based design criteria and reliability-based methods: exploring a new concept / Ghosh, Siddhartha in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1677 - 1698 p.
Titre : Merging energy-based design criteria and reliability-based methods: exploring a new concept Type de document : texte imprimé Auteurs : Ghosh, Siddhartha, Auteur ; Collins, Kevin R., Auteur Article en page(s) : 1677 - 1698 p. Note générale : Génie civil Langues : Anglais (eng) Mots-clés : performance-based seismic design Energy-based design Probabilistic Seismic hazard analysis Uniform hazard spectra Hysteretic energy demand Reliability-based design Conception séismique de performance basé conception énergie Analyse de risque séismique probabiliste Spectres uniformes de risque Demande énergétique par hystérésis Conception de fiabilité Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : This paper examines the potential development of a probabilistic design methodology, considering hysteretic energy demand, within the framework of performance-based seismic design of buildings. This article does not propose specific energy-based criteria for design guidelines, but explores how such criteria can be treated from a probabilistic design perspective. Uniform hazard spectra for normalized hysteretic energy are constructed to characterize seismic demand at a specific site. These spectra, in combination with an equivalent systems methodology, are used to estimate hysteretic energy demand on real building structures. A design checking equation for a (hypothetical) probabilistic energy-based performance criterion is developed by accounting for the randomness of the earthquake phenomenon, the uncertainties associated with the equivalent system analysis technique, and with the site soil factor. The developed design checking equation itself is deterministic, and requires no probabilistic analysis for use. The application of the proposed equation is demonstrated by applying it to a trial design of a three-storey steel moment frame. The design checking equation represents a first step toward the development of a performance-based seismic design procedure based on energy criterion, and additional works needed to fully implement this are discussed in brief at the end of the paper.
Cet article examine l'élaboration potentielle d'une méthodologie probabiliste de conception, vu la demande énergétique par hystérésis, dans le cadre de la conception séismique exécution-basée des bâtiments. Cet article ne propose pas des critères énergie-basés spécifiques pour des directives de conception, mais explore comment de tels critères peuvent être traités d'une perspective probabiliste de conception. Des spectres uniformes de risque pour l'énergie par hystérésis normale sont construits pour caractériser une demande séismique à un emplacement spécifique. Ces spectres, en combination avec les systèmes équivalents méthodologie, sont employés pour estimer la demande énergétique par hystérésis sur de vraies fondations. Une conception examinant l'équation pour assurer le critère énergie-basé probabiliste (hypothétique) d'exécution de a est développée par comptabilité pour l'aspect aléatoire du phénomène de tremblement de terre, les incertitudes liées à la technique équivalente d'analyse de système, et au facteur de sol d'emplacement. La conception développée vérifiant l'équation elle-même est déterministe, et n'exige aucune analyse probabiliste pour l'usage. L'application de l'équation proposée est démontrée en s'appliquant l'à une conception d'essai d'une armature en acier à trois niveaux de moment. La conception vérifiant l'équation représente une première étape vers le développement d'un procédé de conception séismique exécution-basé basé sur le critère d'énergie, et des travaux additionnels requis pour mettre en application entièrement ceci sont discutés en bref à l'extrémité du papier.ISSN : 0098-8847 RAMEAU : Risque seismique -- Génie parasismique En ligne : http://www3.interscience.wiley.com/journal/117869386/issue [article] Merging energy-based design criteria and reliability-based methods: exploring a new concept [texte imprimé] / Ghosh, Siddhartha, Auteur ; Collins, Kevin R., Auteur . - 1677 - 1698 p.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1677 - 1698 p.
Mots-clés : performance-based seismic design Energy-based design Probabilistic Seismic hazard analysis Uniform hazard spectra Hysteretic energy demand Reliability-based design Conception séismique de performance basé conception énergie Analyse de risque séismique probabiliste Spectres uniformes de risque Demande énergétique par hystérésis Conception de fiabilité Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : This paper examines the potential development of a probabilistic design methodology, considering hysteretic energy demand, within the framework of performance-based seismic design of buildings. This article does not propose specific energy-based criteria for design guidelines, but explores how such criteria can be treated from a probabilistic design perspective. Uniform hazard spectra for normalized hysteretic energy are constructed to characterize seismic demand at a specific site. These spectra, in combination with an equivalent systems methodology, are used to estimate hysteretic energy demand on real building structures. A design checking equation for a (hypothetical) probabilistic energy-based performance criterion is developed by accounting for the randomness of the earthquake phenomenon, the uncertainties associated with the equivalent system analysis technique, and with the site soil factor. The developed design checking equation itself is deterministic, and requires no probabilistic analysis for use. The application of the proposed equation is demonstrated by applying it to a trial design of a three-storey steel moment frame. The design checking equation represents a first step toward the development of a performance-based seismic design procedure based on energy criterion, and additional works needed to fully implement this are discussed in brief at the end of the paper.
Cet article examine l'élaboration potentielle d'une méthodologie probabiliste de conception, vu la demande énergétique par hystérésis, dans le cadre de la conception séismique exécution-basée des bâtiments. Cet article ne propose pas des critères énergie-basés spécifiques pour des directives de conception, mais explore comment de tels critères peuvent être traités d'une perspective probabiliste de conception. Des spectres uniformes de risque pour l'énergie par hystérésis normale sont construits pour caractériser une demande séismique à un emplacement spécifique. Ces spectres, en combination avec les systèmes équivalents méthodologie, sont employés pour estimer la demande énergétique par hystérésis sur de vraies fondations. Une conception examinant l'équation pour assurer le critère énergie-basé probabiliste (hypothétique) d'exécution de a est développée par comptabilité pour l'aspect aléatoire du phénomène de tremblement de terre, les incertitudes liées à la technique équivalente d'analyse de système, et au facteur de sol d'emplacement. La conception développée vérifiant l'équation elle-même est déterministe, et n'exige aucune analyse probabiliste pour l'usage. L'application de l'équation proposée est démontrée en s'appliquant l'à une conception d'essai d'une armature en acier à trois niveaux de moment. La conception vérifiant l'équation représente une première étape vers le développement d'un procédé de conception séismique exécution-basé basé sur le critère d'énergie, et des travaux additionnels requis pour mettre en application entièrement ceci sont discutés en bref à l'extrémité du papier.ISSN : 0098-8847 RAMEAU : Risque seismique -- Génie parasismique En ligne : http://www3.interscience.wiley.com/journal/117869386/issue Experimental and analytical studies on earthquake resisting behaviour of confined concrete block masonry structures / Hori, Norio in Earthquake engineering structural dynamics, Vol. 35 N° 13 (Novembre 2006)
[article]
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1699 - 1719
Titre : Experimental and analytical studies on earthquake resisting behaviour of confined concrete block masonry structures Type de document : texte imprimé Auteurs : Hori, Norio, Auteur ; Inoue, Norio, Auteur ; Purushotam, Dangol ; Nishida, Tetsuya ; Kobayashi, Jun, Auteur Article en page(s) : 1699 - 1719 Note générale : Génie civil Langues : Anglais (eng) Mots-clés : Confined masonry structure Concrete block Mortar joint Earthquake resistance Static load test Rigid body spring model Structure confinée de maçonnerie Bloc concret Joint de mortier Résistance de tremblement de terre Essai statique de charge Modèle rigide de ressort de corps Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : To improve the seismic performance of masonry structures, confined masonry that improves the seismic resistance of masonry structures by the confining effect of surrounding bond beams and tie columns is constructed. This study investigated the earthquake resisting behaviour of confined masonry structures that are being studied and constructed in China. The structural system consists of unreinforced block masonry walls with surrounding reinforced concrete bond beams and tie columns. The characteristics of the structure include: (1) damage to blocks is reduced and brittle failure is avoided by the comparatively lower strength of the joint mortar than that of the blocks, (2) the masonry walls and surrounding reinforced concrete bond beams and tie columns are securely jointed by the shear keys of the tie columns. In this study, wall specimens made of concrete blocks were tested under a cyclic lateral load and simulated by a rigid body spring model that models non-linear behaviour by rigid bodies and boundary springs. The results of studies outline the resisting mechanism, indicating that a rigid body spring model is considered appropriate for analysing this type of structure.
Pour améliorer l'exécution séismique des structures de maçonnerie, la maçonnerie confinée qui améliore la résistance séismique des structures de maçonnerie par l'effet d'emprisonnement d'entourer des faisceaux d'obligation et des colonnes de cravate est construite. Cette étude a étudié le comportement de résistance de tremblement de terre des structures confinées de maçonnerie qui sont étudiées et construites en Chine. Le système structural se compose des murs non renforcés de maçonnerie de bloc avec entourer les faisceaux d'obligation et les colonnes concrets renforcés de cravate. Les caractéristiques de la structure incluent : (1) des dommages aux blocs sont réduits et la rupture fragile est évitée par la force comparativement inférieure du mortier commun que cela des blocs, (2) les murs de maçonnerie et les faisceaux d'obligation et les colonnes concrets renforcés d'entourage de cravate sont solidement joints par les clefs de cisaillement des colonnes de cravate. Dans cette étude, des spécimens de mur faits de blocs concrets ont été examinés sous une charge latérale cyclique et simulés par un modèle rigide de ressort de corps qui modèle le comportement non linéaire par les corps et les ressorts rigides de frontière. Les résultats des études décrivent le mécanisme de résistance, indiquant qu'un modèle rigide de ressort de corps est considéré approprié pour analyser ce type de structure.ISSN : 0098-8847 RAMEAU : Essais statiques -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue [article] Experimental and analytical studies on earthquake resisting behaviour of confined concrete block masonry structures [texte imprimé] / Hori, Norio, Auteur ; Inoue, Norio, Auteur ; Purushotam, Dangol ; Nishida, Tetsuya ; Kobayashi, Jun, Auteur . - 1699 - 1719.
Génie civil
Langues : Anglais (eng)
in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1699 - 1719
Mots-clés : Confined masonry structure Concrete block Mortar joint Earthquake resistance Static load test Rigid body spring model Structure confinée de maçonnerie Bloc concret Joint de mortier Résistance de tremblement de terre Essai statique de charge Modèle rigide de ressort de corps Index. décimale : 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels Résumé : To improve the seismic performance of masonry structures, confined masonry that improves the seismic resistance of masonry structures by the confining effect of surrounding bond beams and tie columns is constructed. This study investigated the earthquake resisting behaviour of confined masonry structures that are being studied and constructed in China. The structural system consists of unreinforced block masonry walls with surrounding reinforced concrete bond beams and tie columns. The characteristics of the structure include: (1) damage to blocks is reduced and brittle failure is avoided by the comparatively lower strength of the joint mortar than that of the blocks, (2) the masonry walls and surrounding reinforced concrete bond beams and tie columns are securely jointed by the shear keys of the tie columns. In this study, wall specimens made of concrete blocks were tested under a cyclic lateral load and simulated by a rigid body spring model that models non-linear behaviour by rigid bodies and boundary springs. The results of studies outline the resisting mechanism, indicating that a rigid body spring model is considered appropriate for analysing this type of structure.
Pour améliorer l'exécution séismique des structures de maçonnerie, la maçonnerie confinée qui améliore la résistance séismique des structures de maçonnerie par l'effet d'emprisonnement d'entourer des faisceaux d'obligation et des colonnes de cravate est construite. Cette étude a étudié le comportement de résistance de tremblement de terre des structures confinées de maçonnerie qui sont étudiées et construites en Chine. Le système structural se compose des murs non renforcés de maçonnerie de bloc avec entourer les faisceaux d'obligation et les colonnes concrets renforcés de cravate. Les caractéristiques de la structure incluent : (1) des dommages aux blocs sont réduits et la rupture fragile est évitée par la force comparativement inférieure du mortier commun que cela des blocs, (2) les murs de maçonnerie et les faisceaux d'obligation et les colonnes concrets renforcés d'entourage de cravate sont solidement joints par les clefs de cisaillement des colonnes de cravate. Dans cette étude, des spécimens de mur faits de blocs concrets ont été examinés sous une charge latérale cyclique et simulés par un modèle rigide de ressort de corps qui modèle le comportement non linéaire par les corps et les ressorts rigides de frontière. Les résultats des études décrivent le mécanisme de résistance, indiquant qu'un modèle rigide de ressort de corps est considéré approprié pour analyser ce type de structure.ISSN : 0098-8847 RAMEAU : Essais statiques -- Tremblement de terre En ligne : http://www3.interscience.wiley.com/journal/117869386/issue
Exemplaires
Code-barres | Cote | Support | Localisation | Section | Disponibilité |
---|---|---|---|---|---|
aucun exemplaire |