[article] in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1631 - 1651 p. Titre : | Bench-shelf system dynamic characteristics and their effects on equipment and contents | Type de document : | texte imprimé | Auteurs : | Hutchinson, Tara C., Auteur ; Chaudhuri, Samit Ray, Auteur | Article en page(s) : | 1631 - 1651 p. | Note générale : | Génie civil | Langues : | Anglais (eng) | Mots-clés : | Shake table testing Nonstructural components Dynamic characterization Furniture response Acceleration amplification Essai de table de secousse Composants nonstructural Caractérisation dynamique Réponse de meubles Amplification d'accélération | Index. décimale : | 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels | Résumé : | Economic losses during past earthquakes are strongly associated with damage and failure to nonstructural equipment and contents. Among the vast types of nonstructural elements, one important category, is scientific equipment in biological or chemical laboratories. These equipment are often mounted on heavy ceramic bench-tops of bench-shelf systems, which in turn may amplify the dynamic motions imposed. To investigate the seismic response of these types of systems, a series of shake table and field experiments were conducted considering different representative bench and shelf-mounted equipment and contents.
Results from shake table experiments indicate that these equipment are generally sliding-dominated. In addition, the bench-shelf system is observed to be very stiff and when lightly loaded, has a fundamental frequency between 10 and 16 Hz. An approximate 50% reduction in the first and second fundamental frequencies is observed considering practical loading conditions. Insight into a broader range of system response is provided by conducting eigenvalue and time history analyses. Non-linear regression through the numerical data indicate acceleration amplification ratios range from 2.6 to 1.4 and from 4.3 to 1.6, for fixed-fixed and pinned-pinned conditions, respectively. Both the experimental and numerical results support the importance of determining the potential dynamic amplification of motion in the context of accurately determining the maximum sliding displacement of support equipment and contents.
Des pertes économiques pendant des tremblements de terre passés sont fortement associées aux dommages et à l'échec à l'équipement et au contenu non structural. Parmi les vastes types d'éléments non structural, une catégorie importante, est équipement scientifique dans les laboratoires biologiques ou chimiques. Ces l'équipement sont souvent montés sur mettre hors jeu-tops en céramique lourd des systèmes de mettre hors jeu-shelf, qui alternativement peuvent amplifier les mouvements dynamiques imposés. Pour étudier la réponse séismique de ces types de systèmes, une série de table de secousse et des expériences sur le terrain ont été conduites considérant le représentant différent mettent hors jeu et étagère-ont monté l'équipement et le contenu. Les résultats des expériences de table de secousse indiquent que ces équipements glisser-sont généralement dominés. En outre, le système de mettre hors jeu-shelf est observé pour être très raide et une fois légèrement chargé, a une fréquence fondamentale entre 10 et 16 hertz. On observe une réduction approximative de 50% des premières et deuxièmes fréquences fondamentales considérer des conditions de charge pratiques. L'aperçu d'une plus large gamme de réaction de système est fourni en conduisant des analyses d'histoire de valeur propre et de temps. La régression non linéaire par les données numériques indiquent que des rapports d'amplification d'accélération s'étendent de 2.6 à 1.4 et de 4.3 à 1.6, parce que de conditions fixe-fixes et goupiller-goupillées, respectivement. Les résultats expérimentaux et numériques soutiennent l'importance de déterminer l'amplification dynamique potentiel du mouvement dans le contexte de déterminer exactement le déplacement coulissant de maximum de l'équipement et du contenu de soutien. | ISSN : | 0098-8847 | RAMEAU : | Secousse | En ligne : | http://www3.interscience.wiley.com/journal/117869386/issue |
[article] Bench-shelf system dynamic characteristics and their effects on equipment and contents [texte imprimé] / Hutchinson, Tara C., Auteur ; Chaudhuri, Samit Ray, Auteur . - 1631 - 1651 p. Génie civil Langues : Anglais ( eng) in Earthquake engineering structural dynamics > Vol. 35 N° 13 (Novembre 2006) . - 1631 - 1651 p. Mots-clés : | Shake table testing Nonstructural components Dynamic characterization Furniture response Acceleration amplification Essai de table de secousse Composants nonstructural Caractérisation dynamique Réponse de meubles Amplification d'accélération | Index. décimale : | 624.1 Infrastructures.Ouvrages en terre. Fondations. Tunnels | Résumé : | Economic losses during past earthquakes are strongly associated with damage and failure to nonstructural equipment and contents. Among the vast types of nonstructural elements, one important category, is scientific equipment in biological or chemical laboratories. These equipment are often mounted on heavy ceramic bench-tops of bench-shelf systems, which in turn may amplify the dynamic motions imposed. To investigate the seismic response of these types of systems, a series of shake table and field experiments were conducted considering different representative bench and shelf-mounted equipment and contents.
Results from shake table experiments indicate that these equipment are generally sliding-dominated. In addition, the bench-shelf system is observed to be very stiff and when lightly loaded, has a fundamental frequency between 10 and 16 Hz. An approximate 50% reduction in the first and second fundamental frequencies is observed considering practical loading conditions. Insight into a broader range of system response is provided by conducting eigenvalue and time history analyses. Non-linear regression through the numerical data indicate acceleration amplification ratios range from 2.6 to 1.4 and from 4.3 to 1.6, for fixed-fixed and pinned-pinned conditions, respectively. Both the experimental and numerical results support the importance of determining the potential dynamic amplification of motion in the context of accurately determining the maximum sliding displacement of support equipment and contents.
Des pertes économiques pendant des tremblements de terre passés sont fortement associées aux dommages et à l'échec à l'équipement et au contenu non structural. Parmi les vastes types d'éléments non structural, une catégorie importante, est équipement scientifique dans les laboratoires biologiques ou chimiques. Ces l'équipement sont souvent montés sur mettre hors jeu-tops en céramique lourd des systèmes de mettre hors jeu-shelf, qui alternativement peuvent amplifier les mouvements dynamiques imposés. Pour étudier la réponse séismique de ces types de systèmes, une série de table de secousse et des expériences sur le terrain ont été conduites considérant le représentant différent mettent hors jeu et étagère-ont monté l'équipement et le contenu. Les résultats des expériences de table de secousse indiquent que ces équipements glisser-sont généralement dominés. En outre, le système de mettre hors jeu-shelf est observé pour être très raide et une fois légèrement chargé, a une fréquence fondamentale entre 10 et 16 hertz. On observe une réduction approximative de 50% des premières et deuxièmes fréquences fondamentales considérer des conditions de charge pratiques. L'aperçu d'une plus large gamme de réaction de système est fourni en conduisant des analyses d'histoire de valeur propre et de temps. La régression non linéaire par les données numériques indiquent que des rapports d'amplification d'accélération s'étendent de 2.6 à 1.4 et de 4.3 à 1.6, parce que de conditions fixe-fixes et goupiller-goupillées, respectivement. Les résultats expérimentaux et numériques soutiennent l'importance de déterminer l'amplification dynamique potentiel du mouvement dans le contexte de déterminer exactement le déplacement coulissant de maximum de l'équipement et du contenu de soutien. | ISSN : | 0098-8847 | RAMEAU : | Secousse | En ligne : | http://www3.interscience.wiley.com/journal/117869386/issue |
|