[article]
Titre : |
Advanced high temperature gas-cooled reactor systems |
Type de document : |
texte imprimé |
Auteurs : |
Yasuyoshi Kato, Auteur |
Année de publication : |
2010 |
Article en page(s) : |
07 p. |
Note générale : |
Génie Mécanique |
Langues : |
Anglais (eng) |
Mots-clés : |
Gas cooled reactors turbine power stations Heat exchangers transfer Microchannel flow |
Index. décimale : |
620.1 Essais des matériaux. Défauts des matériaux. Protection des matériaux |
Résumé : |
Three systems have been proposed for advanced high-temperature gas-cooled reactors: a supercritical carbon dioxide (S-CO2) gas turbine power conversion system, a new microchannel heat exchanger (MCHE), and a once-through-then-out (OTTO) refueling scheme with burnable poison (BP) loading. A S-CO2 gas turbine cycle attains higher cycle efficiency than a He gas turbine cycle because of reduced compression work around the critical point of CO2. Considering temperature reduction at the turbine inlet by 30°C through intermediate heat exchange, the S-CO2 indirect cycle achieves an efficiency of 53.8% at a turbine inlet temperature of 820°C and a turbine inlet pressure of 20 MPa. This cycle efficiency value is higher by 4.5% than that (49.3%) of a He direct cycle at a turbine inlet temperature of 850°C and 7 MPa. A new MCHE has been proposed as an intermediate heat exchanger between the primary cooling He loop and the secondary S-CO2 gas turbine power conversion system and as recuperators of the S-CO2 gas turbine power conversion system. This MCHE has discontinuous “S-shaped” fins providing flow channels resembling sine curves. Its pressure drop is one-sixth that of a conventional MCHE with a zigzag flow channel configuration, but it has the same high heat transfer performance. The pressure drop reduction is ascribed to suppression of recirculation flows and eddies that appear around bend corners of the zigzag flow channels in the conventional MCHE. An optimal BP loading in an OTTO refueling scheme eliminates the shortcoming of its excessively high axial power peaking factor, reducing the power peaking factor from 4.44 to about 1.7, and inheriting advantages over the multipass scheme because it obviates reloading in addition to fuel handling and integrity checking systems. Because of the power peaking factor reduction, the maximum fuel temperatures are lower than the maximum permissible values of 1250°C for normal operation and 1600°C during a depressurization accident. |
DEWEY : |
620.1 |
ISSN : |
0742-4795 |
En ligne : |
http://asmedl.org/getabs/servlet/GetabsServlet?prog=normal&id=JETPEZ000132000001 [...] |
in Transactions of the ASME . Journal of engineering for gas turbines and power > Vol. 132 N° 1 (Janvier 2010) . - 07 p.
[article] Advanced high temperature gas-cooled reactor systems [texte imprimé] / Yasuyoshi Kato, Auteur . - 2010 . - 07 p. Génie Mécanique Langues : Anglais ( eng) in Transactions of the ASME . Journal of engineering for gas turbines and power > Vol. 132 N° 1 (Janvier 2010) . - 07 p.
Mots-clés : |
Gas cooled reactors turbine power stations Heat exchangers transfer Microchannel flow |
Index. décimale : |
620.1 Essais des matériaux. Défauts des matériaux. Protection des matériaux |
Résumé : |
Three systems have been proposed for advanced high-temperature gas-cooled reactors: a supercritical carbon dioxide (S-CO2) gas turbine power conversion system, a new microchannel heat exchanger (MCHE), and a once-through-then-out (OTTO) refueling scheme with burnable poison (BP) loading. A S-CO2 gas turbine cycle attains higher cycle efficiency than a He gas turbine cycle because of reduced compression work around the critical point of CO2. Considering temperature reduction at the turbine inlet by 30°C through intermediate heat exchange, the S-CO2 indirect cycle achieves an efficiency of 53.8% at a turbine inlet temperature of 820°C and a turbine inlet pressure of 20 MPa. This cycle efficiency value is higher by 4.5% than that (49.3%) of a He direct cycle at a turbine inlet temperature of 850°C and 7 MPa. A new MCHE has been proposed as an intermediate heat exchanger between the primary cooling He loop and the secondary S-CO2 gas turbine power conversion system and as recuperators of the S-CO2 gas turbine power conversion system. This MCHE has discontinuous “S-shaped” fins providing flow channels resembling sine curves. Its pressure drop is one-sixth that of a conventional MCHE with a zigzag flow channel configuration, but it has the same high heat transfer performance. The pressure drop reduction is ascribed to suppression of recirculation flows and eddies that appear around bend corners of the zigzag flow channels in the conventional MCHE. An optimal BP loading in an OTTO refueling scheme eliminates the shortcoming of its excessively high axial power peaking factor, reducing the power peaking factor from 4.44 to about 1.7, and inheriting advantages over the multipass scheme because it obviates reloading in addition to fuel handling and integrity checking systems. Because of the power peaking factor reduction, the maximum fuel temperatures are lower than the maximum permissible values of 1250°C for normal operation and 1600°C during a depressurization accident. |
DEWEY : |
620.1 |
ISSN : |
0742-4795 |
En ligne : |
http://asmedl.org/getabs/servlet/GetabsServlet?prog=normal&id=JETPEZ000132000001 [...] |
|