[article]
Titre : |
Response of a polyvinyl chloride water pipe when transverse to an underlying pipe replaced by pipe bursting |
Type de document : |
texte imprimé |
Auteurs : |
J. A. Cholewa, Auteur ; R. W. I. Brachman, Auteur ; I. D. Moore, Auteur |
Article en page(s) : |
pp. 1258–1266 |
Note générale : |
Sciences de la Terre |
Langues : |
Anglais (eng) |
Mots-clés : |
Pipe bursting Adjacent utility Displacement Longitudinal strain Laboratory testing Eclatement de tuyau Services adjacents Déplacement Déformation longitudinale Essais en laboratoire |
Index. décimale : |
550 Sciences auxiliaires de la géologie. |
Résumé : |
An existing deteriorated or hydraulically undersized pipe can be replaced with a new pipe by static pipe bursting. Cavity expansion during pipe bursting induces ground movements, which may potentially damage nearby buried utilities if they are in close proximity to the pipe bursting operation. A large-scale pipe bursting experiment was performed in an 8 m long, 8 m wide, and 3 m deep test pit filled with a well-graded sand and gravel soil. A polyvinyl chloride (PVC) pipe, crossing transversely and 0.45 m above the existing pipe being replaced, was instrumented with strain gages to quantify the response of that transverse utility to the ground movements associated with pipe bursting. In this paper, the measured strain and corresponding deflection of the PVC pipe are examined and compared with measurements of surface uplift. The maximum longitudinal strain measured in the pipe was less than 0.1% and its vertical diameter decreased by only 0.5%, suggesting that ground displacements induced by pipe bursting did not jeopardize the transverse water pipe’s long-term performance, provided its joints were not damaged. A simplified design equation is introduced and shown to provide estimates of maximum longitudinal strain in the PVC pipe close to those measured during the laboratory experiment.
Un tuyau existant trop petit ou détérioré peu être remplacé par un nouveau tuyau par la méthode de l’éclatement statique du tuyau. L’expansion de la cavité pendant l’éclatement du tuyau provoque des mouvements dans le sol qui peuvent potentiellement causer des dommages aux services enfouis s’ils sont près de l’opération d’éclatement du tuyau. Un essai à grande échelle d’éclatement du tuyau a été effectué dans une fosse d’essai de 8 m de longueur, 8 m de largeur et 3 m de profondeur remplie avec du sable non uniforme et du gravier. Un tuyau de chlorure de polyvinyle (« PVC ») placé 0,45 m (transversal) au-dessus du tuyau à changer a été instrumenté afin de quantifier le comportement de tuyaux de services transversaux lors de du remplacement d’un tuyau adjacent par la méthode de l’éclatement du tuyau. Les déformations mesurées et les déflections correspondantes sur le tuyau de PVC sont examinées et comparées aux mesures de soulèvement de la surface. La déformation longitudinale maximale mesurée sur le tuyau était inférieure à 0,1 % et son diamètre vertical s’est réduit de seulement 0,5 %, ce qui indique que les déplacements du sol causés par l’éclatement du tuyau n’ont pas mis en danger les performances à long terme du tuyau d’eau, en supposant que ses joints n’ont pas été endommagés. Une équation de conception simplifiée est présentée et démontre qu’elle permet d’obtenir des estimations des déformations longitudinales maximales dans le tuyau de chlorure de polyvinyle qui sont près de celles mesurées en laboratoire.
|
DEWEY : |
550 |
ISSN : |
0008-3674 |
En ligne : |
http://rparticle.web-p.cisti.nrc.ca/rparticle/AbstractTemplateServlet?calyLang=f [...] |
in Canadian geotechnical journal > Vol. 46 N° 11 (Novembre 2009) . - pp. 1258–1266
[article] Response of a polyvinyl chloride water pipe when transverse to an underlying pipe replaced by pipe bursting [texte imprimé] / J. A. Cholewa, Auteur ; R. W. I. Brachman, Auteur ; I. D. Moore, Auteur . - pp. 1258–1266. Sciences de la Terre Langues : Anglais ( eng) in Canadian geotechnical journal > Vol. 46 N° 11 (Novembre 2009) . - pp. 1258–1266
Mots-clés : |
Pipe bursting Adjacent utility Displacement Longitudinal strain Laboratory testing Eclatement de tuyau Services adjacents Déplacement Déformation longitudinale Essais en laboratoire |
Index. décimale : |
550 Sciences auxiliaires de la géologie. |
Résumé : |
An existing deteriorated or hydraulically undersized pipe can be replaced with a new pipe by static pipe bursting. Cavity expansion during pipe bursting induces ground movements, which may potentially damage nearby buried utilities if they are in close proximity to the pipe bursting operation. A large-scale pipe bursting experiment was performed in an 8 m long, 8 m wide, and 3 m deep test pit filled with a well-graded sand and gravel soil. A polyvinyl chloride (PVC) pipe, crossing transversely and 0.45 m above the existing pipe being replaced, was instrumented with strain gages to quantify the response of that transverse utility to the ground movements associated with pipe bursting. In this paper, the measured strain and corresponding deflection of the PVC pipe are examined and compared with measurements of surface uplift. The maximum longitudinal strain measured in the pipe was less than 0.1% and its vertical diameter decreased by only 0.5%, suggesting that ground displacements induced by pipe bursting did not jeopardize the transverse water pipe’s long-term performance, provided its joints were not damaged. A simplified design equation is introduced and shown to provide estimates of maximum longitudinal strain in the PVC pipe close to those measured during the laboratory experiment.
Un tuyau existant trop petit ou détérioré peu être remplacé par un nouveau tuyau par la méthode de l’éclatement statique du tuyau. L’expansion de la cavité pendant l’éclatement du tuyau provoque des mouvements dans le sol qui peuvent potentiellement causer des dommages aux services enfouis s’ils sont près de l’opération d’éclatement du tuyau. Un essai à grande échelle d’éclatement du tuyau a été effectué dans une fosse d’essai de 8 m de longueur, 8 m de largeur et 3 m de profondeur remplie avec du sable non uniforme et du gravier. Un tuyau de chlorure de polyvinyle (« PVC ») placé 0,45 m (transversal) au-dessus du tuyau à changer a été instrumenté afin de quantifier le comportement de tuyaux de services transversaux lors de du remplacement d’un tuyau adjacent par la méthode de l’éclatement du tuyau. Les déformations mesurées et les déflections correspondantes sur le tuyau de PVC sont examinées et comparées aux mesures de soulèvement de la surface. La déformation longitudinale maximale mesurée sur le tuyau était inférieure à 0,1 % et son diamètre vertical s’est réduit de seulement 0,5 %, ce qui indique que les déplacements du sol causés par l’éclatement du tuyau n’ont pas mis en danger les performances à long terme du tuyau d’eau, en supposant que ses joints n’ont pas été endommagés. Une équation de conception simplifiée est présentée et démontre qu’elle permet d’obtenir des estimations des déformations longitudinales maximales dans le tuyau de chlorure de polyvinyle qui sont près de celles mesurées en laboratoire.
|
DEWEY : |
550 |
ISSN : |
0008-3674 |
En ligne : |
http://rparticle.web-p.cisti.nrc.ca/rparticle/AbstractTemplateServlet?calyLang=f [...] |
|