[article]
Titre : |
Shear strength testing of intact and recompacted samples of municipal solid waste |
Type de document : |
texte imprimé |
Auteurs : |
Manoj K. Singh, Auteur ; Jitendra S. Sharma, Auteur ; Ian R. Fleming, Auteur |
Article en page(s) : |
pp. 1133-1145 |
Note générale : |
Sciences de la Terre |
Langues : |
Anglais (eng) |
Mots-clés : |
Municipal solid waste Sampling technique Shear strength Triaxial testing Direct shear Déchets municipaux solides Technique d’échantillonnage Résistance au cisaillement Essai triaxial de direct |
Index. décimale : |
550 Sciences auxiliaires de la géologie. |
Résumé : |
This paper presents results of shear strength testing of intact and recompacted samples of municipal solid waste (MSW). A method for in situ sampling of MSW from landfills using a push-in sampler was developed and used to obtain intact samples of MSW from a large municipal landfill. Shear strength testing of MSW was carried out using a large triaxial compression apparatus as well as a large direct shear apparatus. The results are presented in terms of cohesion intercept (c′) and angle of shearing resistance () and are compared with those available in published literature. Based on these results and their favourable comparison with this literature, it can be concluded that meaningful shear strength parameters for MSW can be obtained using consolidated undrained triaxial tests on large-diameter intact and recompacted samples. A fairly consistent picture of the shear behaviour of MSW obtained from effective stress paths in triaxial tests appears to suggest that shear behaviour of MSW can be explained using the effective stress principle. It is suggested that recompacted samples could be used for obtaining reasonable estimates of c′ and for MSW; however, it may be necessary to use intact samples to establish the pre-failure deformation behaviour of MSW.
Cet article présente les résultats d’essai de résistance au cisaillement d’échantillons intacts et recompactés provenant de déchets municipaux solides (DMS). Une méthode pour l’échantillonnage in situ des DMS à l’aide d’un échantillonneur « push-in » a été développée et utilisée pour obtenir des échantillons intacts de DMS d’un grand dépotoir municipal. Les essais de résistance au cisaillement des DMS ont été effectués avec un gros appareil de compression triaxiale ainsi qu’un gros appareil de cisaillement direct. Les résultats sont présentés en termes de cohésion (c′) et d’angle de résistance au cisaillement (), et sont comparés aux valeurs de la littérature. Selon ces résultats et ceux comparables dans la littérature publiée, on peut conclure que des paramètres de résistance au cisaillement significatifs pour les DMS peuvent être obtenus à partir d’essais triaxiaux consolidés non drainés effectués sur des échantillons de grand diamètre intacts ou recompactés. Un comportement en cisaillement des DMS relativement consistent obtenu à partir des cheminements des contraintes effectives semble suggérer que le comportement en cisaillement des DMS peut être expliqué à partir du principe des contraintes effectives. L’étude propose aussi que les échantillons recompactés peuvent être utilisés pour obtenir des estimations raisonnables de c′ et pour des DMS; cependant il est possiblement nécessaire d’utiliser des échantillons intacts pour établir le comportement en déformation pré-rupture des DMS.
|
DEWEY : |
550 |
ISSN : |
0008-3674 |
En ligne : |
http://rparticle.web-p.cisti.nrc.ca/rparticle/AbstractTemplateServlet?calyLang=f [...] |
in Canadian geotechnical journal > Vol. 46 N° 10 (Octobre 2009) . - pp. 1133-1145
[article] Shear strength testing of intact and recompacted samples of municipal solid waste [texte imprimé] / Manoj K. Singh, Auteur ; Jitendra S. Sharma, Auteur ; Ian R. Fleming, Auteur . - pp. 1133-1145. Sciences de la Terre Langues : Anglais ( eng) in Canadian geotechnical journal > Vol. 46 N° 10 (Octobre 2009) . - pp. 1133-1145
Mots-clés : |
Municipal solid waste Sampling technique Shear strength Triaxial testing Direct shear Déchets municipaux solides Technique d’échantillonnage Résistance au cisaillement Essai triaxial de direct |
Index. décimale : |
550 Sciences auxiliaires de la géologie. |
Résumé : |
This paper presents results of shear strength testing of intact and recompacted samples of municipal solid waste (MSW). A method for in situ sampling of MSW from landfills using a push-in sampler was developed and used to obtain intact samples of MSW from a large municipal landfill. Shear strength testing of MSW was carried out using a large triaxial compression apparatus as well as a large direct shear apparatus. The results are presented in terms of cohesion intercept (c′) and angle of shearing resistance () and are compared with those available in published literature. Based on these results and their favourable comparison with this literature, it can be concluded that meaningful shear strength parameters for MSW can be obtained using consolidated undrained triaxial tests on large-diameter intact and recompacted samples. A fairly consistent picture of the shear behaviour of MSW obtained from effective stress paths in triaxial tests appears to suggest that shear behaviour of MSW can be explained using the effective stress principle. It is suggested that recompacted samples could be used for obtaining reasonable estimates of c′ and for MSW; however, it may be necessary to use intact samples to establish the pre-failure deformation behaviour of MSW.
Cet article présente les résultats d’essai de résistance au cisaillement d’échantillons intacts et recompactés provenant de déchets municipaux solides (DMS). Une méthode pour l’échantillonnage in situ des DMS à l’aide d’un échantillonneur « push-in » a été développée et utilisée pour obtenir des échantillons intacts de DMS d’un grand dépotoir municipal. Les essais de résistance au cisaillement des DMS ont été effectués avec un gros appareil de compression triaxiale ainsi qu’un gros appareil de cisaillement direct. Les résultats sont présentés en termes de cohésion (c′) et d’angle de résistance au cisaillement (), et sont comparés aux valeurs de la littérature. Selon ces résultats et ceux comparables dans la littérature publiée, on peut conclure que des paramètres de résistance au cisaillement significatifs pour les DMS peuvent être obtenus à partir d’essais triaxiaux consolidés non drainés effectués sur des échantillons de grand diamètre intacts ou recompactés. Un comportement en cisaillement des DMS relativement consistent obtenu à partir des cheminements des contraintes effectives semble suggérer que le comportement en cisaillement des DMS peut être expliqué à partir du principe des contraintes effectives. L’étude propose aussi que les échantillons recompactés peuvent être utilisés pour obtenir des estimations raisonnables de c′ et pour des DMS; cependant il est possiblement nécessaire d’utiliser des échantillons intacts pour établir le comportement en déformation pré-rupture des DMS.
|
DEWEY : |
550 |
ISSN : |
0008-3674 |
En ligne : |
http://rparticle.web-p.cisti.nrc.ca/rparticle/AbstractTemplateServlet?calyLang=f [...] |
|