Résumé : |
A novel method is presented for the detection and isolation of open-transistor faults in voltage-source inverters feeding AC motors. The method is an extension of the normalized DC-components method. The normalized average currents are combined with additional diagnostic variables which convey information about the percentage of time spent by the phase currents in the near-zero zone. The combined diagnostic signals permit much more robust diagnostics of single-transistor faults and make feasible the diagnostics of multiple-transistor faults. Suggested in this paper is also an alternative solution for the normalization of DC components, which is easier interpreted and simpler to implement. |
DEWEY : |
621.38 |
ISSN : |
0278-0046 |
En ligne : |
http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5067311 |
in IEEE transactions on industrial electronics > Vol. 56 N° 11 (Novembre 2009) . - pp. 4681 - 4688
[article] Open-transistor fault diagnostics in voltage-source inverters by analyzing the load currents [texte imprimé] / Sleszynski, Wojciech, Auteur ; Nieznanski, Janusz, Auteur ; Cichowski, Artur, Auteur . - pp. 4681 - 4688. Génie électrique Langues : Anglais ( eng) in IEEE transactions on industrial electronics > Vol. 56 N° 11 (Novembre 2009) . - pp. 4681 - 4688
Mots-clés : |
AC motor drives Fault diagnosis Pulsewidth modulated inverters |
Index. décimale : |
621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X |
Résumé : |
A novel method is presented for the detection and isolation of open-transistor faults in voltage-source inverters feeding AC motors. The method is an extension of the normalized DC-components method. The normalized average currents are combined with additional diagnostic variables which convey information about the percentage of time spent by the phase currents in the near-zero zone. The combined diagnostic signals permit much more robust diagnostics of single-transistor faults and make feasible the diagnostics of multiple-transistor faults. Suggested in this paper is also an alternative solution for the normalization of DC components, which is easier interpreted and simpler to implement. |