Auteur Shedid, Marwan T.
Documents disponibles écrits par cet auteur
Affiner la rechercheAlternative strategies to enhance the seismic performance of reinforced concrete-block shear wall systems / Shedid, Marwan T. in Journal of structural engineering, Vol. 136 N° 6 (Juin 2010)
[article]
in Journal of structural engineering > Vol. 136 N° 6 (Juin 2010) . - pp. 676-689
Titre : Alternative strategies to enhance the seismic performance of reinforced concrete-block shear wall systems Type de document : texte imprimé Auteurs : Shedid, Marwan T., Auteur ; El-Dakhakhni, Wael W., Auteur ; Drysdale, Robert G., Auteur Année de publication : 2011 Article en page(s) : pp. 676-689 Note générale : Génie Civil Langues : Anglais (eng) Mots-clés : Concrete masonry Cyclic loads Ductility Experimental tests Flanges Seismic tests Shear walls Index. décimale : 624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes Résumé : In this paper, seven reinforced concrete-block shear walls with aspect ratios of 1.5 and 2.2 (two- and three-storey high) were tested under displacement-controlled cyclic loading. The response of rectangular, flanged, and end-confined walls, designed to have the same lateral resistance when subjected to the same axial load, is discussed. In general, high levels of ductility accompanied by relatively small strength degradation were observed in all walls with a significant increase in ductility and displacement capabilities for the flanged and end-confined walls compared to the rectangular ones. For both aspect ratios evaluated, the drift levels at 20% strength degradation were 1.0, 1.5, and 2.2% corresponding to the rectangular, the flanged, and the end-confined walls, respectively. The ductility values of the proposed flanged and end-confined walls were, respectively, 1.5 and 2 times those of their rectangular wall counterparts (with the same overall length and aspect ratio). In addition to the enhanced ductility, a saving of more than 40% in the amount of vertical reinforcement was achieved using the proposed alternative strategies while maintaining the same lateral wall resistance. Existing design clauses were used to predict the wall capacities using the American and the Canadian masonry codes and showed excellent agreement. This will facilitate adoption of the new construction categories with minimal modifications to existing code clauses. The test results indicate that higher ductility than the currently endorsed values by North American codes should be used for rectangular walls. Moreover, higher values should be expected when the proposed strategies are adopted which would significantly reduce the seismic demand on reinforced concrete-block shear wall construction.
DEWEY : 624.17 ISSN : 0733-9445 En ligne : http://ascelibrary.org/sto/resource/1/jsendh/v136/i6/p676_s1?isAuthorized=no [article] Alternative strategies to enhance the seismic performance of reinforced concrete-block shear wall systems [texte imprimé] / Shedid, Marwan T., Auteur ; El-Dakhakhni, Wael W., Auteur ; Drysdale, Robert G., Auteur . - 2011 . - pp. 676-689.
Génie Civil
Langues : Anglais (eng)
in Journal of structural engineering > Vol. 136 N° 6 (Juin 2010) . - pp. 676-689
Mots-clés : Concrete masonry Cyclic loads Ductility Experimental tests Flanges Seismic tests Shear walls Index. décimale : 624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes Résumé : In this paper, seven reinforced concrete-block shear walls with aspect ratios of 1.5 and 2.2 (two- and three-storey high) were tested under displacement-controlled cyclic loading. The response of rectangular, flanged, and end-confined walls, designed to have the same lateral resistance when subjected to the same axial load, is discussed. In general, high levels of ductility accompanied by relatively small strength degradation were observed in all walls with a significant increase in ductility and displacement capabilities for the flanged and end-confined walls compared to the rectangular ones. For both aspect ratios evaluated, the drift levels at 20% strength degradation were 1.0, 1.5, and 2.2% corresponding to the rectangular, the flanged, and the end-confined walls, respectively. The ductility values of the proposed flanged and end-confined walls were, respectively, 1.5 and 2 times those of their rectangular wall counterparts (with the same overall length and aspect ratio). In addition to the enhanced ductility, a saving of more than 40% in the amount of vertical reinforcement was achieved using the proposed alternative strategies while maintaining the same lateral wall resistance. Existing design clauses were used to predict the wall capacities using the American and the Canadian masonry codes and showed excellent agreement. This will facilitate adoption of the new construction categories with minimal modifications to existing code clauses. The test results indicate that higher ductility than the currently endorsed values by North American codes should be used for rectangular walls. Moreover, higher values should be expected when the proposed strategies are adopted which would significantly reduce the seismic demand on reinforced concrete-block shear wall construction.
DEWEY : 624.17 ISSN : 0733-9445 En ligne : http://ascelibrary.org/sto/resource/1/jsendh/v136/i6/p676_s1?isAuthorized=no Characteristics of rectangular, flanged, and end-confined reinforced concrete masonry shear walls for seismic design / Shedid, Marwan T. in Journal of structural engineering, Vol. 136 N° 12 (Décembre 2010)
[article]
in Journal of structural engineering > Vol. 136 N° 12 (Décembre 2010) . - pp. 1471-1482
Titre : Characteristics of rectangular, flanged, and end-confined reinforced concrete masonry shear walls for seismic design Type de document : texte imprimé Auteurs : Shedid, Marwan T., Auteur ; El-Dakhakhni, Wael W., Auteur ; Drysdale, Robert G., Auteur Année de publication : 2011 Article en page(s) : pp. 1471-1482 Note générale : Génie Civil Langues : Anglais (eng) Mots-clés : Concrete masonry Cyclic loads Ductility Experimental tests Flanges Seismic tests Shear walls Index. décimale : 624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes Résumé : This paper contains detailed analyses of an experimental study conducted to evaluate the ductility, stiffness degradation and energy dissipation characteristics of rectangular, flanged, and end-confined reinforced masonry (RM) shear walls failing in flexure. The test program consisted of seven two- and three-story RM shear walls, with aspect ratios of 1.5 and 2.2, tested under reversed cyclic lateral displacements simulating seismic loading effects. Documentation of the compressive strains at the wall toes, wall base curvatures, and ductility levels attained are presented. The paper focuses on determining the extent of plasticity over the wall height, evaluating the contribution of flexure and shear deformations to the overall wall lateral displacements, identifying the trend of stiffness degradation, and quantifying the amount of energy dissipation. The rectangular walls displacement predictions at ultimate loads using Canadian Standards Association (CSA) S304.1 were in better agreement with the experimental results compared to the Masonry Standards Joint Committee (MSJC) code predictions. However, both the MSJC code and the CSA S304.1 significantly overestimated the test results for the flanged and end-confined walls. Analysis of the measured displacements showed that the contribution of shear displacement to the overall wall displacement was, on average, 21 and 25% of the total displacement for the walls with aspect ratio of 2.2 and 1.5, respectively. The relationship between the energy dissipation and the ratio of the postyield to the yield displacements was found to be almost linear for the test walls. In addition, the wall stiffnesses degraded rapidly to about 60% of their gross stiffness at very low drift levels (0.1% drift). Measured compressive strain at the wall toes were almost double those specified in both North American codes. Extent of plasticity over the wall height was about 75% of the wall length. The data presented in this paper is expected to facilitate better understanding of RM wall behavior under in-plane load to researchers, practicing engineers, and code developers. This study aimed at presenting the flanged and end-confined categories as cost-effective alternatives to enhance the seismic performance of midrise RM construction in North America.
DEWEY : 624.17 ISSN : 0733-9445 En ligne : http://ascelibrary.org/sto/resource/1/jsendh/v136/i12/p1471_s1?isAuthorized=no [article] Characteristics of rectangular, flanged, and end-confined reinforced concrete masonry shear walls for seismic design [texte imprimé] / Shedid, Marwan T., Auteur ; El-Dakhakhni, Wael W., Auteur ; Drysdale, Robert G., Auteur . - 2011 . - pp. 1471-1482.
Génie Civil
Langues : Anglais (eng)
in Journal of structural engineering > Vol. 136 N° 12 (Décembre 2010) . - pp. 1471-1482
Mots-clés : Concrete masonry Cyclic loads Ductility Experimental tests Flanges Seismic tests Shear walls Index. décimale : 624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes Résumé : This paper contains detailed analyses of an experimental study conducted to evaluate the ductility, stiffness degradation and energy dissipation characteristics of rectangular, flanged, and end-confined reinforced masonry (RM) shear walls failing in flexure. The test program consisted of seven two- and three-story RM shear walls, with aspect ratios of 1.5 and 2.2, tested under reversed cyclic lateral displacements simulating seismic loading effects. Documentation of the compressive strains at the wall toes, wall base curvatures, and ductility levels attained are presented. The paper focuses on determining the extent of plasticity over the wall height, evaluating the contribution of flexure and shear deformations to the overall wall lateral displacements, identifying the trend of stiffness degradation, and quantifying the amount of energy dissipation. The rectangular walls displacement predictions at ultimate loads using Canadian Standards Association (CSA) S304.1 were in better agreement with the experimental results compared to the Masonry Standards Joint Committee (MSJC) code predictions. However, both the MSJC code and the CSA S304.1 significantly overestimated the test results for the flanged and end-confined walls. Analysis of the measured displacements showed that the contribution of shear displacement to the overall wall displacement was, on average, 21 and 25% of the total displacement for the walls with aspect ratio of 2.2 and 1.5, respectively. The relationship between the energy dissipation and the ratio of the postyield to the yield displacements was found to be almost linear for the test walls. In addition, the wall stiffnesses degraded rapidly to about 60% of their gross stiffness at very low drift levels (0.1% drift). Measured compressive strain at the wall toes were almost double those specified in both North American codes. Extent of plasticity over the wall height was about 75% of the wall length. The data presented in this paper is expected to facilitate better understanding of RM wall behavior under in-plane load to researchers, practicing engineers, and code developers. This study aimed at presenting the flanged and end-confined categories as cost-effective alternatives to enhance the seismic performance of midrise RM construction in North America.
DEWEY : 624.17 ISSN : 0733-9445 En ligne : http://ascelibrary.org/sto/resource/1/jsendh/v136/i12/p1471_s1?isAuthorized=no Detection of ungrouted cells in concrete masonry constructions using a dielectric variation approach / El-Dakhakhni, Wael W. in Journal of engineering mechanics, Vol. 136 N° 4 (Avril 2010)
[article]
in Journal of engineering mechanics > Vol. 136 N° 4 (Avril 2010) . - pp. 438-447
Titre : Detection of ungrouted cells in concrete masonry constructions using a dielectric variation approach Type de document : texte imprimé Auteurs : El-Dakhakhni, Wael W., Auteur ; Nassr, Amr A., Auteur ; Shedid, Marwan T., Auteur Article en page(s) : pp. 438-447 Note générale : Mécanique appliquée Langues : Anglais (eng) Mots-clés : Walls Masonry Grouting Probe instruments Damage Measurement Nondestructive tests Concrete construction. Résumé : n this study, a new technique for detecting ungrouted cells in concrete block masonry constructions was developed. The concept, based on detecting the local dielectric permittivity variations, was employed to design coplanar capacitance sensors with high sensitivities to detect such construction defects. An analytical model and finite element simulations were used to assess the influence of the sensor geometrical parameters on the sensor signals and to optimize the sensor design. To experimentally verify the model, the dielectric properties of various materials involved in concrete masonry walls were measured. In addition, a masonry wall containing predetermined grouted and ungrouted cells was constructed and inspected using the developed sensors in a laboratory setting. Moreover, different capacitance sensors were designed and compared with respect to their sensitivity, signal-to-noise ratio, and coefficient of variation of the inspected measurements. Excellent agreements were found between the experimental capacitance signal response parameters and those predicted by the analytical and finite element models. The proposed sensor design, coupled with a commercially available portable capacitance meter, would facilitate employing this technique in the field for rapid inspection of masonry structures without the need for sophisticated data analyses usually required by other more expensive and time consuming methods. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/vsearch/servlet/VerityServlet?KEY=JENMDT&CURRENT=null [...] [article] Detection of ungrouted cells in concrete masonry constructions using a dielectric variation approach [texte imprimé] / El-Dakhakhni, Wael W., Auteur ; Nassr, Amr A., Auteur ; Shedid, Marwan T., Auteur . - pp. 438-447.
Mécanique appliquée
Langues : Anglais (eng)
in Journal of engineering mechanics > Vol. 136 N° 4 (Avril 2010) . - pp. 438-447
Mots-clés : Walls Masonry Grouting Probe instruments Damage Measurement Nondestructive tests Concrete construction. Résumé : n this study, a new technique for detecting ungrouted cells in concrete block masonry constructions was developed. The concept, based on detecting the local dielectric permittivity variations, was employed to design coplanar capacitance sensors with high sensitivities to detect such construction defects. An analytical model and finite element simulations were used to assess the influence of the sensor geometrical parameters on the sensor signals and to optimize the sensor design. To experimentally verify the model, the dielectric properties of various materials involved in concrete masonry walls were measured. In addition, a masonry wall containing predetermined grouted and ungrouted cells was constructed and inspected using the developed sensors in a laboratory setting. Moreover, different capacitance sensors were designed and compared with respect to their sensitivity, signal-to-noise ratio, and coefficient of variation of the inspected measurements. Excellent agreements were found between the experimental capacitance signal response parameters and those predicted by the analytical and finite element models. The proposed sensor design, coupled with a commercially available portable capacitance meter, would facilitate employing this technique in the field for rapid inspection of masonry structures without the need for sophisticated data analyses usually required by other more expensive and time consuming methods. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/vsearch/servlet/VerityServlet?KEY=JENMDT&CURRENT=null [...]