Détail de l'auteur
Auteur Wei Song |
Documents disponibles écrits par cet auteur (3)



Current-Fed Dual-Bridge DC–DC Converter / Wei Song in IEEE transactions on power electronics, Vol. 22 N°2 (Mars 2007)
![]()
[article]
Titre : Current-Fed Dual-Bridge DC–DC Converter Titre original : Convertisseur duel du pont alimenté par courant DC-DC Type de document : texte imprimé Auteurs : Wei Song, Auteur ; Lehman, Brad, Auteur Année de publication : 2007 Article en page(s) : 461-469 p. Note générale : Electronique Langues : Anglais (eng) Mots-clés : Current-fed DC-DC converter Deadtime Duel-bridge Full-bridge Zero voltage switching (ZVS) Courant alimenté Convertisseur Temps mort Pont de duel Plein pont Commutation zéro tension Index. décimale : 621.31 Production,approvisionnement et contrôle de l'électricité.Machines et appareils électriques.Mesure électrique.Magnétisme et électrostatique appliquées
Résumé : A new isolated current-fed pulsewidth modulation dc-dc converter-current-fed dual-bridge dc-dc converter-with small inductance and no deadtime operation is presented and analyzed. The new topology has more than 3times smaller inductance than that of current-fed full-bridge converter, thus having faster transient response speed. Other characteristics include simple self-driven synchronous rectification, simple housekeeping power supply, and smaller output filter capacitance. Detailed analysis shows the proposed converter can have either lower voltage stress on all primary side power switches or soft switching properties when different driving schemes are applied. A 48-V/125-W prototype dc-dc converter with dual output has been tested for the verification of the principles. Both simulations and experiments verify the feasibility and advantages of the new topology.
Un nouveau courant d'isolement a alimenté le convertisseur duel de DC-DC de pont alimenté par courant de convertisseur de DC-DC de modulation de pulsewidth avec la petite inductance et aucune opération de deadtime n'est présentée et est analysée. La nouvelle topologie a plus qu'une plus petite inductance 3times que cela du plein convertisseur de pont alimenté par courant, de ce fait ayant une vitesse plus rapide de réponse passagère. D'autres caractéristiques incluent la rectification synchrone conduite par individu simple, l'alimentation d'énergie simple de ménage, et la plus petite capacité de filtre de rendement. L'analyse détaillée montre que le convertisseur proposé peut avoir l'effort à tension inférieure sur tous les commutateurs de puissance latéraux primaires ou les propriétés molles de commutation quand différents arrangements de conduite sont appliqués. Un convertisseur DC-DC du prototype 48-V/125-W avec le rendement duel a été examiné pour la vérification des principes. Les simulations et les expériences vérifient la praticabilité et les avantages de la nouvelle topologieDEWEY : 621 ISSN : 0885-8993 RAMEAU : Courants électriques-- Commutation (électricité) En ligne : wsong@ece.neu.edu, wayne.song@intel.com
in IEEE transactions on power electronics > Vol. 22 N°2 (Mars 2007) . - 461-469 p.[article] Current-Fed Dual-Bridge DC–DC Converter = Convertisseur duel du pont alimenté par courant DC-DC [texte imprimé] / Wei Song, Auteur ; Lehman, Brad, Auteur . - 2007 . - 461-469 p.
Electronique
Langues : Anglais (eng)
in IEEE transactions on power electronics > Vol. 22 N°2 (Mars 2007) . - 461-469 p.
Mots-clés : Current-fed DC-DC converter Deadtime Duel-bridge Full-bridge Zero voltage switching (ZVS) Courant alimenté Convertisseur Temps mort Pont de duel Plein pont Commutation zéro tension Index. décimale : 621.31 Production,approvisionnement et contrôle de l'électricité.Machines et appareils électriques.Mesure électrique.Magnétisme et électrostatique appliquées
Résumé : A new isolated current-fed pulsewidth modulation dc-dc converter-current-fed dual-bridge dc-dc converter-with small inductance and no deadtime operation is presented and analyzed. The new topology has more than 3times smaller inductance than that of current-fed full-bridge converter, thus having faster transient response speed. Other characteristics include simple self-driven synchronous rectification, simple housekeeping power supply, and smaller output filter capacitance. Detailed analysis shows the proposed converter can have either lower voltage stress on all primary side power switches or soft switching properties when different driving schemes are applied. A 48-V/125-W prototype dc-dc converter with dual output has been tested for the verification of the principles. Both simulations and experiments verify the feasibility and advantages of the new topology.
Un nouveau courant d'isolement a alimenté le convertisseur duel de DC-DC de pont alimenté par courant de convertisseur de DC-DC de modulation de pulsewidth avec la petite inductance et aucune opération de deadtime n'est présentée et est analysée. La nouvelle topologie a plus qu'une plus petite inductance 3times que cela du plein convertisseur de pont alimenté par courant, de ce fait ayant une vitesse plus rapide de réponse passagère. D'autres caractéristiques incluent la rectification synchrone conduite par individu simple, l'alimentation d'énergie simple de ménage, et la plus petite capacité de filtre de rendement. L'analyse détaillée montre que le convertisseur proposé peut avoir l'effort à tension inférieure sur tous les commutateurs de puissance latéraux primaires ou les propriétés molles de commutation quand différents arrangements de conduite sont appliqués. Un convertisseur DC-DC du prototype 48-V/125-W avec le rendement duel a été examiné pour la vérification des principes. Les simulations et les expériences vérifient la praticabilité et les avantages de la nouvelle topologieDEWEY : 621 ISSN : 0885-8993 RAMEAU : Courants électriques-- Commutation (électricité) En ligne : wsong@ece.neu.edu, wayne.song@intel.com Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire Improved damage localization and quantification using subset selection / Wei Song in Journal of engineering mechanics, Vol. 135 N° 6 (Juin 2009)
![]()
[article]
Titre : Improved damage localization and quantification using subset selection Type de document : texte imprimé Auteurs : Wei Song, Auteur ; Shirley Dyke, Auteur ; GunJin Yun, Auteur Article en page(s) : pp. 548-560 Note générale : Mécanique appliquée Langues : Anglais (eng) Mots-clés : Damage Optimization Localization Structural response. Résumé : Because a structure's modal parameters (natural frequencies and mode shapes) are affected by structural damage, finite- element model updating techniques are often applied to locate and quantify structural damage. However, the dynamic behavior of a structure can only be observed in a narrow knowledge space, which usually causes nonuniqueness and ill-posedness in the damage detection problem formulation. Thus, advanced optimization techniques are a necessary tool for solving such a complex inverse problem. Furthermore, a preselection process of the most significant damage parameters is helpful to improve the efficiency of the damage detection procedure. A new approach, which combines a parameter subset selection process with the application of damage functions is proposed herein to accomplish this task. Starting with a simple 1D beam, this paper first demonstrates several essential concepts related to the proposed model updating approach. A more advanced example considering a 2D model is then considered. To determine the capabilities of this approach for more complex structures, a trust region-based optimization method is adopted to solve the corresponding nonlinear minimization problem. The objective is to provide an improved robust solution to this challenging problem. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JENMDT000 [...]
in Journal of engineering mechanics > Vol. 135 N° 6 (Juin 2009) . - pp. 548-560[article] Improved damage localization and quantification using subset selection [texte imprimé] / Wei Song, Auteur ; Shirley Dyke, Auteur ; GunJin Yun, Auteur . - pp. 548-560.
Mécanique appliquée
Langues : Anglais (eng)
in Journal of engineering mechanics > Vol. 135 N° 6 (Juin 2009) . - pp. 548-560
Mots-clés : Damage Optimization Localization Structural response. Résumé : Because a structure's modal parameters (natural frequencies and mode shapes) are affected by structural damage, finite- element model updating techniques are often applied to locate and quantify structural damage. However, the dynamic behavior of a structure can only be observed in a narrow knowledge space, which usually causes nonuniqueness and ill-posedness in the damage detection problem formulation. Thus, advanced optimization techniques are a necessary tool for solving such a complex inverse problem. Furthermore, a preselection process of the most significant damage parameters is helpful to improve the efficiency of the damage detection procedure. A new approach, which combines a parameter subset selection process with the application of damage functions is proposed herein to accomplish this task. Starting with a simple 1D beam, this paper first demonstrates several essential concepts related to the proposed model updating approach. A more advanced example considering a 2D model is then considered. To determine the capabilities of this approach for more complex structures, a trust region-based optimization method is adopted to solve the corresponding nonlinear minimization problem. The objective is to provide an improved robust solution to this challenging problem. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JENMDT000 [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire Modal identification through ambient vibration / Giraldo, Diego F. in Journal of engineering mechanics, Vol. 135 N° 8 (Août 2009)
![]()
[article]
Titre : Modal identification through ambient vibration : comparative study Type de document : texte imprimé Auteurs : Giraldo, Diego F., Auteur ; Wei Song, Auteur ; Dyke, Shirley J., Auteur Année de publication : 2009 Article en page(s) : pp. 759-770 Note générale : Mécanique appliquée Langues : Anglais (eng) Mots-clés : Vibration Modal analysis Comparative studies Structural analysis. Résumé : An analytical comparison between three techniques for the identification of modal properties of structures when subjected to ambient vibrations is performed. The algorithms examined include the eigensystem realization algorithm with data correlations, the prediction error method through least squares, and the stochastic subspace identification (SSI) technique. Both analytical and experimental data from a four-storey building scaled at 1:3 are used to perform these evaluations. The level of noise added to the simulated data is varied to study the robustness of the techniques. All techniques are fully automated, allowing for assessments to be conducted through Monte Carlo simulations. The results indicate that the SSI technique provides the most accurate identification of natural frequencies and mode shapes even with high noise levels, all while requiring the least amount of experience for implementation. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/vsearch/servlet/VerityServlet?KEY=JENMDT&smode=strres [...]
in Journal of engineering mechanics > Vol. 135 N° 8 (Août 2009) . - pp. 759-770[article] Modal identification through ambient vibration : comparative study [texte imprimé] / Giraldo, Diego F., Auteur ; Wei Song, Auteur ; Dyke, Shirley J., Auteur . - 2009 . - pp. 759-770.
Mécanique appliquée
Langues : Anglais (eng)
in Journal of engineering mechanics > Vol. 135 N° 8 (Août 2009) . - pp. 759-770
Mots-clés : Vibration Modal analysis Comparative studies Structural analysis. Résumé : An analytical comparison between three techniques for the identification of modal properties of structures when subjected to ambient vibrations is performed. The algorithms examined include the eigensystem realization algorithm with data correlations, the prediction error method through least squares, and the stochastic subspace identification (SSI) technique. Both analytical and experimental data from a four-storey building scaled at 1:3 are used to perform these evaluations. The level of noise added to the simulated data is varied to study the robustness of the techniques. All techniques are fully automated, allowing for assessments to be conducted through Monte Carlo simulations. The results indicate that the SSI technique provides the most accurate identification of natural frequencies and mode shapes even with high noise levels, all while requiring the least amount of experience for implementation. DEWEY : 620.1 ISSN : 0733-9399 En ligne : http://ascelibrary.aip.org/vsearch/servlet/VerityServlet?KEY=JENMDT&smode=strres [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire