Résumé : |
In this paper, the influence of one-sample delay for sampling and computation in digital control on the bandwidth of the inner current loop of a 400-Hz ground power unit (GPU) is analyzed first. The results show that it is difficult and even impossible for high-power 400-Hz GPUs to maintain low total harmonic distortion content in the output voltage with the conventional proportional-integral-based double-loop control. To improve the performance, resonant controllers with parallel structure which are widely used in active power filters are applied to the single-loop control of the 400-Hz GPU. The parameter design criterion for the parallel resonant controllers is discussed in the discrete time domain. Meanwhile, adoption of proportional gain in the single-loop control is investigated. The results show that it can improve the performance little and may cause instability problems. Comparisons between different control methods for the 400-Hz GPU are also made, and the single-loop control method in this paper seems to be the most suitable one in terms of simplicity and performance. Experiments on a 16-b fixed-point DSP-controlled 90-kVA 400-Hz GPU prototype show satisfactory results of the single-loop method feeding linear/nonlinear and balanced/unbalanced loads. |
DEWEY : |
621.38 |
ISSN : |
0278-0046 |
En ligne : |
http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5280265 |
in IEEE transactions on industrial electronics > Vol. 57 N° 2 (Fevrier 2010) . - pp. 532 - 543
[article] Single-loop digital control of high-power 400-Hz ground power unit for airplanes [texte imprimé] / Li, Zixin, Auteur ; Li, Yaohua, Auteur ; Wang, Ping, Auteur . - pp. 532 - 543. Génie électrique Langues : Anglais ( eng) in IEEE transactions on industrial electronics > Vol. 57 N° 2 (Fevrier 2010) . - pp. 532 - 543
Mots-clés : |
Digital control Resonant controller Single-loop 400-Hz inverter |
Index. décimale : |
621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X |
Résumé : |
In this paper, the influence of one-sample delay for sampling and computation in digital control on the bandwidth of the inner current loop of a 400-Hz ground power unit (GPU) is analyzed first. The results show that it is difficult and even impossible for high-power 400-Hz GPUs to maintain low total harmonic distortion content in the output voltage with the conventional proportional-integral-based double-loop control. To improve the performance, resonant controllers with parallel structure which are widely used in active power filters are applied to the single-loop control of the 400-Hz GPU. The parameter design criterion for the parallel resonant controllers is discussed in the discrete time domain. Meanwhile, adoption of proportional gain in the single-loop control is investigated. The results show that it can improve the performance little and may cause instability problems. Comparisons between different control methods for the 400-Hz GPU are also made, and the single-loop control method in this paper seems to be the most suitable one in terms of simplicity and performance. Experiments on a 16-b fixed-point DSP-controlled 90-kVA 400-Hz GPU prototype show satisfactory results of the single-loop method feeding linear/nonlinear and balanced/unbalanced loads. |