[article]
Titre : |
Experimental seismic response of a full-scale six-story light-frame wood building |
Type de document : |
texte imprimé |
Auteurs : |
John W. Van De Lindt, Auteur ; Shiling Pei, Auteur ; Steven E. Pryor, Auteur |
Année de publication : |
2011 |
Article en page(s) : |
pp. 1262-1272 |
Note générale : |
Génie Civil |
Langues : |
Anglais (eng) |
Mots-clés : |
Shake table testing Seismic tests Earthquake Woodframe Light-frame wood Midrise building |
Index. décimale : |
624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes |
Résumé : |
In July 2009, a full-scale midrise light-frame wood apartment building was subjected to a series of earthquakes at the world’s largest shake table in Miki, Japan. This article focuses on the test results of that full-scale six-story light-frame wood building. The objectives of the testing program were to (1) demonstrate that the performance-based seismic design procedure developed as part of the NEESWood project worked on the full-scale building, i.e., validate the design philosophy to the extent one test can and (2) gain a better understanding of how midrise light-frame wood buildings respond, in general, to a major earthquake while providing a landmark data set to the seismic engineering research community. The building consisted of 1,350 m2 (14,000 ft2) of living space and had 23 apartment units; approximately one-half one-bedroom units and one-half two-bedroom units. The building was subjected to three earthquakes ranging from seismic intensities corresponding to the 72-year event to the 2,500-year event for Los Angeles. In this paper, the construction of the NEESWood Capstone Building is explained and the resulting seismic response in terms of base shears, selected wall drifts, global interstory drifts, accelerations, hold-down forces, and roof drifts are presented. Detailed damage inspection was performed following each test and those results are summarized also. The building performed excellently with little damage even following the 2,500-year earthquake. The global drift at roof level was approximately 0.25 m and maximum interstory drifts were approximately 2% for the floor average with individual wall drifts reaching just over 3% in one corner of the building at the fifth story.
|
DEWEY : |
624.17 |
ISSN : |
0733-9445 |
En ligne : |
http://ascelibrary.org/sto/resource/1/jsendh/v136/i10/p1262_s1?isAuthorized=no |
in Journal of structural engineering > Vol. 136 N° 10 (Octobre 2010) . - pp. 1262-1272
[article] Experimental seismic response of a full-scale six-story light-frame wood building [texte imprimé] / John W. Van De Lindt, Auteur ; Shiling Pei, Auteur ; Steven E. Pryor, Auteur . - 2011 . - pp. 1262-1272. Génie Civil Langues : Anglais ( eng) in Journal of structural engineering > Vol. 136 N° 10 (Octobre 2010) . - pp. 1262-1272
Mots-clés : |
Shake table testing Seismic tests Earthquake Woodframe Light-frame wood Midrise building |
Index. décimale : |
624 Constructions du génie civil et du bâtiment. Infrastructures. Ouvrages en terres. Fondations. Tunnels. Ponts et charpentes |
Résumé : |
In July 2009, a full-scale midrise light-frame wood apartment building was subjected to a series of earthquakes at the world’s largest shake table in Miki, Japan. This article focuses on the test results of that full-scale six-story light-frame wood building. The objectives of the testing program were to (1) demonstrate that the performance-based seismic design procedure developed as part of the NEESWood project worked on the full-scale building, i.e., validate the design philosophy to the extent one test can and (2) gain a better understanding of how midrise light-frame wood buildings respond, in general, to a major earthquake while providing a landmark data set to the seismic engineering research community. The building consisted of 1,350 m2 (14,000 ft2) of living space and had 23 apartment units; approximately one-half one-bedroom units and one-half two-bedroom units. The building was subjected to three earthquakes ranging from seismic intensities corresponding to the 72-year event to the 2,500-year event for Los Angeles. In this paper, the construction of the NEESWood Capstone Building is explained and the resulting seismic response in terms of base shears, selected wall drifts, global interstory drifts, accelerations, hold-down forces, and roof drifts are presented. Detailed damage inspection was performed following each test and those results are summarized also. The building performed excellently with little damage even following the 2,500-year earthquake. The global drift at roof level was approximately 0.25 m and maximum interstory drifts were approximately 2% for the floor average with individual wall drifts reaching just over 3% in one corner of the building at the fifth story.
|
DEWEY : |
624.17 |
ISSN : |
0733-9445 |
En ligne : |
http://ascelibrary.org/sto/resource/1/jsendh/v136/i10/p1262_s1?isAuthorized=no |
|