[article]
Titre : |
Improved controller performance of selected hybrid SOFC-GT plant signals based on practical control schemes |
Type de document : |
texte imprimé |
Auteurs : |
Alex Tsai, Auteur ; David Tucker, Auteur ; Craig Groves, Auteur |
Année de publication : |
2011 |
Article en page(s) : |
11 p. |
Note générale : |
Turbines à gaz |
Langues : |
Anglais (eng) |
Mots-clés : |
Cathodes Centralised control Decentralised Fuel cell power plants Gas turbine stations Hybrid systems MIMO Multivariable Power generation Solid oxide fuel cells Three-term Transfer functions |
Index. décimale : |
620.1 Essais des matériaux. Défauts des matériaux. Protection des matériaux |
Résumé : |
This paper compares and demonstrates the efficacy of implementing two practical single input single output multiloop control schemes on the dynamic performance of selected signals of a solid oxide fuel cell gas turbine (SOFC-GT) hybrid simulation facility. The hybrid plant located at the U.S. Department of Energy National Energy Technology Laboratory in Morgantown, WV is capable of simulating the interaction between a 350 kW solid oxide fuel cell and a 120 kW gas turbine using a hardware in the loop configuration. Previous studies have shown that the thermal management of coal based SOFC-GT hybrid systems is accomplished by the careful control of the cathode air stream within the fuel cell (FC). Decoupled centralized and dynamic decentralized control schemes are tested for one critical airflow bypass loop to regulate cathode FC airflow and modulation of turbine electric load to maintain synchronous turbine speed during system transients. Improvements to the studied multivariate architectures include: feed-forward control for disturbance rejection, antiwindup compensation for actuator saturation, gain scheduling for adaptive operation, bumpless transfer for manual to auto switching, and adequate filter design for the inclusion of derivative action. Controller gain tuning is accomplished by Skogestad's internal model control tuning rules derived from empirical first order plus delay time transfer function models of the hybrid facility. Avoidance of strong input-output coupling interactions is achieved via relative gain array, Niederlinski index, and decomposed relative interaction analysis, following recent methodologies in proportional integral derivative control theory for multivariable processes. |
DEWEY : |
620.1 |
ISSN : |
0742-4795 |
En ligne : |
http://asmedl.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JETPEZ00013300 [...] |
in Transactions of the ASME . Journal of engineering for gas turbines and power > Vol. 133 N° 7 (Juillet 2011) . - 11 p.
[article] Improved controller performance of selected hybrid SOFC-GT plant signals based on practical control schemes [texte imprimé] / Alex Tsai, Auteur ; David Tucker, Auteur ; Craig Groves, Auteur . - 2011 . - 11 p. Turbines à gaz Langues : Anglais ( eng) in Transactions of the ASME . Journal of engineering for gas turbines and power > Vol. 133 N° 7 (Juillet 2011) . - 11 p.
Mots-clés : |
Cathodes Centralised control Decentralised Fuel cell power plants Gas turbine stations Hybrid systems MIMO Multivariable Power generation Solid oxide fuel cells Three-term Transfer functions |
Index. décimale : |
620.1 Essais des matériaux. Défauts des matériaux. Protection des matériaux |
Résumé : |
This paper compares and demonstrates the efficacy of implementing two practical single input single output multiloop control schemes on the dynamic performance of selected signals of a solid oxide fuel cell gas turbine (SOFC-GT) hybrid simulation facility. The hybrid plant located at the U.S. Department of Energy National Energy Technology Laboratory in Morgantown, WV is capable of simulating the interaction between a 350 kW solid oxide fuel cell and a 120 kW gas turbine using a hardware in the loop configuration. Previous studies have shown that the thermal management of coal based SOFC-GT hybrid systems is accomplished by the careful control of the cathode air stream within the fuel cell (FC). Decoupled centralized and dynamic decentralized control schemes are tested for one critical airflow bypass loop to regulate cathode FC airflow and modulation of turbine electric load to maintain synchronous turbine speed during system transients. Improvements to the studied multivariate architectures include: feed-forward control for disturbance rejection, antiwindup compensation for actuator saturation, gain scheduling for adaptive operation, bumpless transfer for manual to auto switching, and adequate filter design for the inclusion of derivative action. Controller gain tuning is accomplished by Skogestad's internal model control tuning rules derived from empirical first order plus delay time transfer function models of the hybrid facility. Avoidance of strong input-output coupling interactions is achieved via relative gain array, Niederlinski index, and decomposed relative interaction analysis, following recent methodologies in proportional integral derivative control theory for multivariable processes. |