Résumé : |
Solar desiccant-based air-conditioning has the potential to significantly reduce cost and/or greenhouse gas emissions associated with cooling of buildings. Parasitic energy consumption for the operation of supply fans has been identified as a major hindrance to achieving these savings. The cooling performance is governed by the trade-off between supplying larger flow-rates of cool air or lower flow-rates of cold air. The performance of a combined solid desiccant-indirect evaporative cooler system is analysed by solving the heat and mass transfer equations for both components simultaneously. Focus is placed on varying the desiccant wheel supply/regeneration and indirect cooler secondary/primary air-flow ratios. Results show that for an ambient reference condition, and 70 °C regeneration temperature, a supply/regeneration flow ratio of 0.67 and an indirect cooler secondary/primary flow ratio of 0.3 gives the best performance with COPe > 20. The proposed cooling system thus has potential to achieve substantial energy and greenhouse gas emission savings. |
DEWEY : |
621.5 |
ISSN : |
0140-7007 |
En ligne : |
http://www.sciencedirect.com/science/article/pii/S0140700710001519 |
in International journal of refrigeration > Vol. 34 N° 1 (Janvier 2011) . - pp. 148-158
[article] Optimisation of a desiccant cooling system design with indirect evaporative cooler = Optimisation de la conception d'un système de refroidissement à déshydratant à refroidissement évaporatif indirect [texte imprimé] / M. Goldsworthy, Auteur ; S. White, Auteur . - 2011 . - pp. 148-158. Génie Mécanique Langues : Anglais ( eng) in International journal of refrigeration > Vol. 34 N° 1 (Janvier 2011) . - pp. 148-158
Mots-clés : |
Air-conditioning Desiccant system wheel Optimisation Performance |
Index. décimale : |
621.5 Energie pneumatique. Machinerie et outils. Réfrigération |
Résumé : |
Solar desiccant-based air-conditioning has the potential to significantly reduce cost and/or greenhouse gas emissions associated with cooling of buildings. Parasitic energy consumption for the operation of supply fans has been identified as a major hindrance to achieving these savings. The cooling performance is governed by the trade-off between supplying larger flow-rates of cool air or lower flow-rates of cold air. The performance of a combined solid desiccant-indirect evaporative cooler system is analysed by solving the heat and mass transfer equations for both components simultaneously. Focus is placed on varying the desiccant wheel supply/regeneration and indirect cooler secondary/primary air-flow ratios. Results show that for an ambient reference condition, and 70 °C regeneration temperature, a supply/regeneration flow ratio of 0.67 and an indirect cooler secondary/primary flow ratio of 0.3 gives the best performance with COPe > 20. The proposed cooling system thus has potential to achieve substantial energy and greenhouse gas emission savings. |