| Titre : | Experimental comparison of multi-layered La–Fe–Co–Si and single-layered Gd active magnetic regenerators for use in a room-temperature magnetic refrigerator (2014) |
| Titre original : | Comparaison expérimentale de réfrigérateurs au La-Fe-Co-Si à couches multiples et au Gd à couches simples pour l'utilisation dans un réfrigérateur magnétique à température ambiante |
| Auteurs : | Jaka Tušek, Auteur ; Andrej Kitanovski, Auteur ; Urban Tomc, Auteur |
| Type de document : | Article : texte imprimé |
| Dans : | International journal of refrigeration (Vol. 37 N° 1, Janvier 2014) |
| Article en page(s) : | pp. 117-126 |
| Note générale : | Refrigeration |
| Langues : | Anglais |
| Tags : | Magnetic refrigeration ; active magnetic regenerator ; magnetocaloric materials ; experiments ; heat transfer |
| Résumé : | We present experimental comparison of different parallel-plate active magnetic regenerators (AMRs) with two different groups of magnetocaloric materials. First, a gadolinium-based single-layered AMR was tested and analysed under different operating conditions. In the next step, three different multi-layered AMRs with different compositions and different Curie temperatures made from LaFe13 − x − yCoxSiy materials were constructed and tested. Seven-, four- and two-layered La-based AMRs were evaluated. The measurements were performed with respect to the maximum measured temperature span under different operating conditions and the cooling load under different temperature spans. In order to find the optimum operating temperature range the AMRs were further compared for different hot-side temperatures. The Gd-based AMR produced a larger temperature span, especially at higher operating frequencies and higher mass-flow rates. Among the multi-layered La–Fe–Co–Si AMRs, the seven- and four-layered AMRs showed very similar characteristics, while the two-layered AMR was much poorer. |
| En ligne : | http://www.sciencedirect.com/science/article/pii/S0140700713002363 |