A 1-kW small horizontal-axis wind turbine “Airdolphin,” capable of high wind operation up to 50 m/s without pitch control system, is now under global round robin tests. The present paper reports a series of technical approach including design/analysis, track tests, and field tests conducted in support to the design process. One windy site “Erimo” and one offshore site “Fukushima” were chosen. For example, at “Erimo,” a record of one-day generation was 8.831 kWh on November 13, 2006 (day-averaged wind speed; 11.8 m/s) with 36.8% of capacity factor. An operation data under an attack of typhoon with 50 m/s maximum wind speed demonstrated the technical concepts of high wind operation and safety. A new term “capatureability” as an indicator of WT performance was proposed.
|
DEWEY : |
621.47 |
ISSN : |
0199-6231 |
En ligne : |
http://asmedl.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JSEEDO00013200 [...] |
in Transactions of the ASME. Journal of solar energy engineering > Vol. 132 N° 1 (Janvier 2010) . - pp. [011002/1-8]
[article] Field operation and track tests of 1-kW small wind turbine under high wind conditions [texte imprimé] / Hikaru Matsumiya, Auteur ; Ryosuke Ito, Auteur ; Masafumi Kawakami, Auteur . - 2010 . - pp. [011002/1-8]. Energie Solaire Langues : Anglais ( eng) in Transactions of the ASME. Journal of solar energy engineering > Vol. 132 N° 1 (Janvier 2010) . - pp. [011002/1-8]
Mots-clés : |
Smal wind turbine Field test Track High operation Captureability |
Index. décimale : |
621.47 |
Résumé : |
A 1-kW small horizontal-axis wind turbine “Airdolphin,” capable of high wind operation up to 50 m/s without pitch control system, is now under global round robin tests. The present paper reports a series of technical approach including design/analysis, track tests, and field tests conducted in support to the design process. One windy site “Erimo” and one offshore site “Fukushima” were chosen. For example, at “Erimo,” a record of one-day generation was 8.831 kWh on November 13, 2006 (day-averaged wind speed; 11.8 m/s) with 36.8% of capacity factor. An operation data under an attack of typhoon with 50 m/s maximum wind speed demonstrated the technical concepts of high wind operation and safety. A new term “capatureability” as an indicator of WT performance was proposed.
|
DEWEY : |
621.47 |
ISSN : |
0199-6231 |
En ligne : |
http://asmedl.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JSEEDO00013200 [...] |
|