Titre : |
Performance analysis of double stage evaporator/absorber for a large temperature difference absorption system |
Titre original : |
Analyse de la performance d’un évaporateur/absorbeur biétagé au sein d’un systéme á absorption á grand écart de température |
Type de document : |
texte imprimé |
Auteurs : |
Chan Woo Park, Auteur ; Yong Tae Kang, Auteur |
Année de publication : |
2010 |
Article en page(s) : |
pp. 521-528 |
Note générale : |
Génie Mécanique |
Langues : |
Anglais (eng) |
Mots-clés : |
Absorption system Water-lithium bromide Double-stage Calculation Performance Coefficient of performance Parameter Temperature difference Chilled water |
Résumé : |
The characteristics of double stage evaporator/absorber are studied to realize a large temperature difference absorption system. In the case of the double stage evaporator/absorber with the large temperature difference of the chilled water (15 °C/7 °C), the pressure of the lower stage in the evaporator/absorber is higher than that of the upper stage. And the concentration of the absorber for the double stage is lower than that for the single stage. If the solution flow ratio decreases with a constant concentration of strong solution of 63.7%, COP increases to 1.19 in the double stage system, which is 12.0% higher than that for the conventional system. When absorber and evaporator are divided by the same ratio, the optimum value of UAR for COP improvement is found to be 0.65.When absorber and evaporator are divided by different ratios, the optimum values of UARE and UARA are (0.6, 0.7). |
DEWEY : |
621.5 |
ISSN : |
0140-7007 |
En ligne : |
http://www.sciencedirect.com/science/article/pii/S014070070900231X |
in International journal of refrigeration > Vol. 33 N° 3 (Mai 2010) . - pp. 521-528
[article] Performance analysis of double stage evaporator/absorber for a large temperature difference absorption system = Analyse de la performance d’un évaporateur/absorbeur biétagé au sein d’un systéme á absorption á grand écart de température [texte imprimé] / Chan Woo Park, Auteur ; Yong Tae Kang, Auteur . - 2010 . - pp. 521-528. Génie Mécanique Langues : Anglais ( eng) in International journal of refrigeration > Vol. 33 N° 3 (Mai 2010) . - pp. 521-528
Mots-clés : |
Absorption system Water-lithium bromide Double-stage Calculation Performance Coefficient of performance Parameter Temperature difference Chilled water |
Résumé : |
The characteristics of double stage evaporator/absorber are studied to realize a large temperature difference absorption system. In the case of the double stage evaporator/absorber with the large temperature difference of the chilled water (15 °C/7 °C), the pressure of the lower stage in the evaporator/absorber is higher than that of the upper stage. And the concentration of the absorber for the double stage is lower than that for the single stage. If the solution flow ratio decreases with a constant concentration of strong solution of 63.7%, COP increases to 1.19 in the double stage system, which is 12.0% higher than that for the conventional system. When absorber and evaporator are divided by the same ratio, the optimum value of UAR for COP improvement is found to be 0.65.When absorber and evaporator are divided by different ratios, the optimum values of UARE and UARA are (0.6, 0.7). |
DEWEY : |
621.5 |
ISSN : |
0140-7007 |
En ligne : |
http://www.sciencedirect.com/science/article/pii/S014070070900231X |
|