| Titre : | Etude et optimisation energétique d'un groupe de puissance hybride (Diesel/PV/Batteries) : Application à une chambre froide pour Le stockage des dattes à ADRAR. |
| Auteurs : | Ikram Bezazel, Auteur ; Bouzid Benkoussas, Directeur de publication |
| Type de document : | texte imprimé |
| Editeur : | [S.l.] : [s.n.], 2026 |
| Format : | 1 fichier PDF (3 Mo) / ill. |
| Note générale : |
Mode d'accès :accès au texte intégral par intranet
Mémoire de Projet de Fin d'Études:Génie Mécanique:Alger, École Nationale Polytechnique :2026 |
| Langues : | Français |
| Index. décimale : | PM00326 |
| Tags : | Hybrid power system Energy management Dispatch Health-Aware Combined Dispatch Strategy HOMER Pro MATLAB, Refrigerated Cold Room. |
| Résumé : |
Abstract:This final year project (PFE) focuses on optimizing the energy management of a standalone hybrid
system combining a photovoltaic (PV) generator, a Diesel generator set, and a battery storage system, intended to supply a date cold storage facility located in Fenoughil, Adrar Province (Algeria). First, a literature review is conducted to analyze the various architectures of hybrid systems, their components, and the main energy management strategies used in the literature. A mixed DC/AC architecture is then adopted for its flexibility and its ability to ensure efficient distribution of energy flows between the different sources. A mathematical modeling of the system's main components is subsequently developed under MATLAB in order to accurately represent the overall behavior of the hybrid system.The optimal sizing of the installation is carried out using HOMER Pro, based on the climatic data of the Fenoughil site and the annual load profile of the cold storage facility.The main originality of this work lies in the development of a new energy management strategy called Health-Aware Combined Dispatch (HACD).The HACD strategy is implemented in MATLAB using an hourly simulation algorithm over a ten-year period. The performance obtained is compared to that of the classical Combined Dispatch strategy through several energy and economic indicators.The results show that the proposed strategy significantly improves the overall performance of the hybrid system. The integration of equipment health- related criteria makes it possible to optimize power distribution while reducing operating costs and operational constraints. |
Exemplaires (1)
| Code-barres | Cote | Support | Localisation | Section | Disponibilité | Spécialité | Etat_Exemplaire | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| EP1151 | PM00326 | Ressources électroniques | Bibliothèque centrale | Projet Fin d'Etudes | Disponible | Genie_mecanique | Téléchargeable |

