Titre : |
A comparison of phase doppler analyzer (dual-PDA) and optical patternator data for twin-fluid and pressure-swirl atomizer sprays |
Type de document : |
texte imprimé |
Auteurs : |
Ariel R. Muliadi, Auteur ; Paul E. Sojka, Auteur ; Yudaya R. Sivathanu, Auteur |
Année de publication : |
2010 |
Article en page(s) : |
10 p. |
Note générale : |
fluids engineering |
Langues : |
Anglais (eng) |
Mots-clés : |
pressure measurement drops sprays |
Résumé : |
The goal of this study was to determine when patternation information derived from Phase Doppler Analyzer (Dantec Dynamics, Skovlunde, Denmark, dual-PDA) measurements of volume flux, drop velocity, and mean size agreed with corresponding values measured using an optical patternator (Enurga, Inc., West Lafayette, IN, SetScan OP-600). To achieve this, data from each instrument were transformed into spatially resolved absorptances (equivalent to drop surface area per unit spray volume) and compared. Key conclusion is absorptance agreement to within 20% in many cases. However, discrepancies between phase Doppler analyzer (PDA)-calculated and optical patternator-measured absorptances become larger as the drop arrival rate increases, as the mean drop size decreases, and when a significant drop size-velocity correlation is present. These discrepancies are attributed to an underestimation of the volume flux (which becomes more important with increasing droplet arrival rate), an over-reporting of the mean drop diameter (which is the result of the restrictive data acquisition scheme applied when ensuring mass closure for the PDA measurements), the limited PDA dynamic range (which can preclude simultaneously accounting for both the largest and smallest drops in the spray), and by the optical patternator’s number-density based measurement scheme (which will not yield the same results as the flux-based PDA when a drop size-velocity correlation is present). |
DEWEY : |
620.1 |
ISSN : |
0098-2202 |
En ligne : |
http://fluidsengineering.asmedigitalcollection.asme.org/issue.aspx?journalid=122 [...] |
in Transactions of the ASME . Journal of fluids engineering > Vol. 132 N° 6 (Juin 2010) . - 10 p.
[article] A comparison of phase doppler analyzer (dual-PDA) and optical patternator data for twin-fluid and pressure-swirl atomizer sprays [texte imprimé] / Ariel R. Muliadi, Auteur ; Paul E. Sojka, Auteur ; Yudaya R. Sivathanu, Auteur . - 2010 . - 10 p. fluids engineering Langues : Anglais ( eng) in Transactions of the ASME . Journal of fluids engineering > Vol. 132 N° 6 (Juin 2010) . - 10 p.
Mots-clés : |
pressure measurement drops sprays |
Résumé : |
The goal of this study was to determine when patternation information derived from Phase Doppler Analyzer (Dantec Dynamics, Skovlunde, Denmark, dual-PDA) measurements of volume flux, drop velocity, and mean size agreed with corresponding values measured using an optical patternator (Enurga, Inc., West Lafayette, IN, SetScan OP-600). To achieve this, data from each instrument were transformed into spatially resolved absorptances (equivalent to drop surface area per unit spray volume) and compared. Key conclusion is absorptance agreement to within 20% in many cases. However, discrepancies between phase Doppler analyzer (PDA)-calculated and optical patternator-measured absorptances become larger as the drop arrival rate increases, as the mean drop size decreases, and when a significant drop size-velocity correlation is present. These discrepancies are attributed to an underestimation of the volume flux (which becomes more important with increasing droplet arrival rate), an over-reporting of the mean drop diameter (which is the result of the restrictive data acquisition scheme applied when ensuring mass closure for the PDA measurements), the limited PDA dynamic range (which can preclude simultaneously accounting for both the largest and smallest drops in the spray), and by the optical patternator’s number-density based measurement scheme (which will not yield the same results as the flux-based PDA when a drop size-velocity correlation is present). |
DEWEY : |
620.1 |
ISSN : |
0098-2202 |
En ligne : |
http://fluidsengineering.asmedigitalcollection.asme.org/issue.aspx?journalid=122 [...] |
|