[article]
Titre : |
Effect of voltage and load variations on efficiencies of a motor-pump system |
Type de document : |
texte imprimé |
Auteurs : |
Kini, P.G., Auteur ; Bansal, R. C., Auteur |
Année de publication : |
2010 |
Article en page(s) : |
pp. 287 - 292 |
Note générale : |
energy conversion |
Langues : |
Anglais (eng) |
Mots-clés : |
centrifuges induction motor drives pumps |
Résumé : |
Centrifugal pumps are the most widely used ac-motor-driven pump systems mainly for water pumping applications. Due to increasing and varying load demand, voltage variation and unbalance is a reality and has to be dealt with carefully. Studies on motor-driven systems under conditions of voltage unbalance have either neglected or maintained constant magnitude of the rotational loss component and focused only on the motor performance while system side performances have not been discussed generally. This paper presents the experimental results of a three-phase induction motor-pump system subjected to voltage and load variations with a view to justify that knowledge of voltage and load variations are very much essential for better result analysis. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5350688&sortType%3Das [...] |
in IEEE transactions on energy conversion > Vol. 25 N° 2 (Juin 2010) . - pp. 287 - 292
[article] Effect of voltage and load variations on efficiencies of a motor-pump system [texte imprimé] / Kini, P.G., Auteur ; Bansal, R. C., Auteur . - 2010 . - pp. 287 - 292. energy conversion Langues : Anglais ( eng) in IEEE transactions on energy conversion > Vol. 25 N° 2 (Juin 2010) . - pp. 287 - 292
Mots-clés : |
centrifuges induction motor drives pumps |
Résumé : |
Centrifugal pumps are the most widely used ac-motor-driven pump systems mainly for water pumping applications. Due to increasing and varying load demand, voltage variation and unbalance is a reality and has to be dealt with carefully. Studies on motor-driven systems under conditions of voltage unbalance have either neglected or maintained constant magnitude of the rotational loss component and focused only on the motor performance while system side performances have not been discussed generally. This paper presents the experimental results of a three-phase induction motor-pump system subjected to voltage and load variations with a view to justify that knowledge of voltage and load variations are very much essential for better result analysis. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5350688&sortType%3Das [...] |
|