[article]
Titre : |
Performance of an isolated nduction generator under unbalanced loads |
Type de document : |
texte imprimé |
Auteurs : |
Idjdarene, K., Auteur ; Rekioua, D., Auteur ; Rekioua, T., Auteur |
Année de publication : |
2010 |
Article en page(s) : |
pp. 303 - 311 |
Note générale : |
energy conversion |
Langues : |
Anglais (eng) |
Mots-clés : |
asynchronous generators Park model saturation effect self-excited induction generator (SEIG) unbalanced load |
Résumé : |
In this paper, the performance of an isolated self-excited induction generator driven by a wind turbine under unbalanced loads is studied. First, the whole system, including the induction generator, the capacitors, and the loads, is modeled. The model used for the isolated induction generator is a diphase one obtained, using the Park transformation. This model allows the saturation effect to be taken into account, assuming certain simplifying hypotheses. Then, the developed model is validated comparing simulation and experiment results at no load and for balanced load cases. Finally, the same model is used to study the performance of the isolated induction generator under unbalanced load cases. Compared to the experiments, the simulation results show a good prediction of the electrical variable waveforms. Furthermore, it can be seen that the magnitude and frequency of the voltages do not vary a lot even if the load is hardly unbalanced. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5353693&sortType%3Das [...] |
in IEEE transactions on energy conversion > Vol. 25 N° 2 (Juin 2010) . - pp. 303 - 311
[article] Performance of an isolated nduction generator under unbalanced loads [texte imprimé] / Idjdarene, K., Auteur ; Rekioua, D., Auteur ; Rekioua, T., Auteur . - 2010 . - pp. 303 - 311. energy conversion Langues : Anglais ( eng) in IEEE transactions on energy conversion > Vol. 25 N° 2 (Juin 2010) . - pp. 303 - 311
Mots-clés : |
asynchronous generators Park model saturation effect self-excited induction generator (SEIG) unbalanced load |
Résumé : |
In this paper, the performance of an isolated self-excited induction generator driven by a wind turbine under unbalanced loads is studied. First, the whole system, including the induction generator, the capacitors, and the loads, is modeled. The model used for the isolated induction generator is a diphase one obtained, using the Park transformation. This model allows the saturation effect to be taken into account, assuming certain simplifying hypotheses. Then, the developed model is validated comparing simulation and experiment results at no load and for balanced load cases. Finally, the same model is used to study the performance of the isolated induction generator under unbalanced load cases. Compared to the experiments, the simulation results show a good prediction of the electrical variable waveforms. Furthermore, it can be seen that the magnitude and frequency of the voltages do not vary a lot even if the load is hardly unbalanced. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5353693&sortType%3Das [...] |
|