[article]
Titre : |
Novel identification method of stator single phase-to-ground fault for cable-wound generators |
Type de document : |
texte imprimé |
Auteurs : |
Gao, Yan, Auteur ; Xiangning Lin, Auteur ; Qing Tian, Auteur |
Année de publication : |
2008 |
Article en page(s) : |
pp. 349 - 357 |
Note générale : |
Energy conversion |
Langues : |
Anglais (eng) |
Mots-clés : |
Electric generators electrical faults fault diagnosis stators |
Résumé : |
A new criterion to detect the stator single phase-to-ground fault for Powerformer is proposed in this paper, which is based on the direction of zero-sequence compositive power flow. By virtue of the analysis of new fault characteristics of Powerformer and the comparison with conventional methods, a novel identification scheme is put forward. The proposed approach detects the ground fault by analyzing the power direction. Only zero-sequence current from the terminal of Powerformer and zero-sequence voltage from the busbar are used in this scheme. Combined with third-harmonic principle, it can provide a 100% coverage of fault detection for the stator windings of Powerformer. The effectiveness of this scheme is validated with the Matlab simulation results. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=4505389&sortType%3Das [...] |
in IEEE transactions on energy conversion > Vol. 23 n°2 (Juin 2008) . - pp. 349 - 357
[article] Novel identification method of stator single phase-to-ground fault for cable-wound generators [texte imprimé] / Gao, Yan, Auteur ; Xiangning Lin, Auteur ; Qing Tian, Auteur . - 2008 . - pp. 349 - 357. Energy conversion Langues : Anglais ( eng) in IEEE transactions on energy conversion > Vol. 23 n°2 (Juin 2008) . - pp. 349 - 357
Mots-clés : |
Electric generators electrical faults fault diagnosis stators |
Résumé : |
A new criterion to detect the stator single phase-to-ground fault for Powerformer is proposed in this paper, which is based on the direction of zero-sequence compositive power flow. By virtue of the analysis of new fault characteristics of Powerformer and the comparison with conventional methods, a novel identification scheme is put forward. The proposed approach detects the ground fault by analyzing the power direction. Only zero-sequence current from the terminal of Powerformer and zero-sequence voltage from the busbar are used in this scheme. Combined with third-harmonic principle, it can provide a 100% coverage of fault detection for the stator windings of Powerformer. The effectiveness of this scheme is validated with the Matlab simulation results. |
En ligne : |
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=4505389&sortType%3Das [...] |
|