Détail de l'auteur
Auteur Paul Symolon |
Documents disponibles écrits par cet auteur (1)



Friction factor measurements in an equally spaced triangular array of circular tubes / Peter Vassallo in Transactions of the ASME . Journal of fluids engineering, Vol. 130 N° 4 (Avril 2008)
![]()
[article]
Titre : Friction factor measurements in an equally spaced triangular array of circular tubes Type de document : texte imprimé Auteurs : Peter Vassallo, Auteur ; Paul Symolon, Auteur Année de publication : 2009 Article en page(s) : 5 p. Note générale : Fluids engineering Langues : Anglais (eng) Mots-clés : Friction factor data adiabatic cross flow circular tube Résumé : Friction factor data for adiabatic cross flow of water in a staggered tube array were obtained over a Reynolds number range (based on hydraulic diameter and gap velocity) of about 10,000–250,000. The tubes were 12.7mm(0.5in.) outer diameter in a uniformly spaced triangular arrangement with a pitch-to-diameter ratio of 1.5. The friction factor was compared to several literature correlations and was found to be best matched by the Idelchik correlation. Other correlations were found to significantly vary from the test data. Based on the test data, a new correlation is proposed for this tube bundle geometry, which covers the entire Reynolds number range tested. En ligne : http://fluidsengineering.asmedigitalcollection.asme.org/Issue.aspx?issueID=27307 [...]
in Transactions of the ASME . Journal of fluids engineering > Vol. 130 N° 4 (Avril 2008) . - 5 p.[article] Friction factor measurements in an equally spaced triangular array of circular tubes [texte imprimé] / Peter Vassallo, Auteur ; Paul Symolon, Auteur . - 2009 . - 5 p.
Fluids engineering
Langues : Anglais (eng)
in Transactions of the ASME . Journal of fluids engineering > Vol. 130 N° 4 (Avril 2008) . - 5 p.
Mots-clés : Friction factor data adiabatic cross flow circular tube Résumé : Friction factor data for adiabatic cross flow of water in a staggered tube array were obtained over a Reynolds number range (based on hydraulic diameter and gap velocity) of about 10,000–250,000. The tubes were 12.7mm(0.5in.) outer diameter in a uniformly spaced triangular arrangement with a pitch-to-diameter ratio of 1.5. The friction factor was compared to several literature correlations and was found to be best matched by the Idelchik correlation. Other correlations were found to significantly vary from the test data. Based on the test data, a new correlation is proposed for this tube bundle geometry, which covers the entire Reynolds number range tested. En ligne : http://fluidsengineering.asmedigitalcollection.asme.org/Issue.aspx?issueID=27307 [...] Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire