[article] in Journal of engineering mechanics > Vol.131, N° 3 (March 2005) . - 268-275 p. Titre : | System Identification of Base-Isolated Building Using Seismic Response Data | Titre original : | Identification de Système du Bâtiment Base-d'Isolement en Utilisant des Données Séismiques de Réponse | Type de document : | texte imprimé | Auteurs : | Noori, M. N., Auteur ; Furukawa, T., Auteur ; Ito M. ; Izawa, K. | Article en page(s) : | 268-275 p. | Note générale : | Génie Civil, Génie Mécanique | Langues : | Anglais (eng) | Mots-clés : | Identification Base isolation Seismic response Hysteretic systems Earthquakes Nonlinear systems Structural models | Index. décimale : | 621.34/624 | Résumé : | Due to the complex nature of the excitation, and the inherent dynamics characteristics of restoring force of the base isolation systems, the response of base-isolated structures subject to strong earthquakes often experiences excursion into the inelastic range. Therefore, in design base-isolated structures, the nonlinear hysteretic restoring force model of the base isolation system is frequently used to predict structural response and to evaluate structural safety. In this paper, the prediction error method system identification technique is used in conjunction with nonlinear state-space models for identification of a base-isolated structure. Using a variety of nonlinear restoring force models and bidirectional recorded seismic responses, several identification runs are conducted to evaluate the accuracy of the selected models. Several nonlinear restoring force models are utilized for the base-isolation systems, including a multiple shear spring (MSS) model. Among all models used, results indicate that the trilinear hysteretic MSS model closely matches the actual hysteretic restoring force profile and time histories obtained directly from the observed data.
En raison de la nature complexe de l'excitation, et des caractéristiques inhérentes de dynamique de reconstituer la force des systèmes bas d'isolement, la réponse des structures base-d'isolement sujet aux tremblements de terre forts éprouve souvent l'excursion dans la gamme non élastique. Par conséquent, en structures base-d'isolement par conception, le modèle de reconstitution par hystérésis non-linéaire de force du système bas d'isolement est fréquemment employé pour prévoir la réponse structurale et pour évaluer la sûreté structurale. En cet article, la technique d'identification de système de méthode d'erreur de prévision est employée en même temps que les modèles non-linéaires de l'état-espace pour l'identification d'une structure base-d'isolement. En utilisant une variété de modèles de reconstitution non-linéaires de force et de réponses séismiques enregistrées bidirectionnelles, plusieurs courses d'identification sont conduites pour évaluer l'exactitude des modèles choisis. Plusieurs modèles de reconstitution non-linéaires de force sont utilisés pour les systèmes d'base-isolement, y compris un modèle multiple du ressort de cisaillement (MSS). Parmi tous les modèles utilisés, les résultats indiquent que le modèle par hystérésis trilinear de MSS assortit étroitement les histoires de reconstitution par hystérésis réelles de profil et de temps de force obtenues directement à partir des données observées.
| En ligne : | furukawa@dali.nuac.nagoya-u.ac.jp |
[article] System Identification of Base-Isolated Building Using Seismic Response Data = Identification de Système du Bâtiment Base-d'Isolement en Utilisant des Données Séismiques de Réponse [texte imprimé] / Noori, M. N., Auteur ; Furukawa, T., Auteur ; Ito M. ; Izawa, K. . - 268-275 p. Génie Civil, Génie Mécanique Langues : Anglais ( eng) in Journal of engineering mechanics > Vol.131, N° 3 (March 2005) . - 268-275 p. Mots-clés : | Identification Base isolation Seismic response Hysteretic systems Earthquakes Nonlinear systems Structural models | Index. décimale : | 621.34/624 | Résumé : | Due to the complex nature of the excitation, and the inherent dynamics characteristics of restoring force of the base isolation systems, the response of base-isolated structures subject to strong earthquakes often experiences excursion into the inelastic range. Therefore, in design base-isolated structures, the nonlinear hysteretic restoring force model of the base isolation system is frequently used to predict structural response and to evaluate structural safety. In this paper, the prediction error method system identification technique is used in conjunction with nonlinear state-space models for identification of a base-isolated structure. Using a variety of nonlinear restoring force models and bidirectional recorded seismic responses, several identification runs are conducted to evaluate the accuracy of the selected models. Several nonlinear restoring force models are utilized for the base-isolation systems, including a multiple shear spring (MSS) model. Among all models used, results indicate that the trilinear hysteretic MSS model closely matches the actual hysteretic restoring force profile and time histories obtained directly from the observed data.
En raison de la nature complexe de l'excitation, et des caractéristiques inhérentes de dynamique de reconstituer la force des systèmes bas d'isolement, la réponse des structures base-d'isolement sujet aux tremblements de terre forts éprouve souvent l'excursion dans la gamme non élastique. Par conséquent, en structures base-d'isolement par conception, le modèle de reconstitution par hystérésis non-linéaire de force du système bas d'isolement est fréquemment employé pour prévoir la réponse structurale et pour évaluer la sûreté structurale. En cet article, la technique d'identification de système de méthode d'erreur de prévision est employée en même temps que les modèles non-linéaires de l'état-espace pour l'identification d'une structure base-d'isolement. En utilisant une variété de modèles de reconstitution non-linéaires de force et de réponses séismiques enregistrées bidirectionnelles, plusieurs courses d'identification sont conduites pour évaluer l'exactitude des modèles choisis. Plusieurs modèles de reconstitution non-linéaires de force sont utilisés pour les systèmes d'base-isolement, y compris un modèle multiple du ressort de cisaillement (MSS). Parmi tous les modèles utilisés, les résultats indiquent que le modèle par hystérésis trilinear de MSS assortit étroitement les histoires de reconstitution par hystérésis réelles de profil et de temps de force obtenues directement à partir des données observées.
| En ligne : | furukawa@dali.nuac.nagoya-u.ac.jp |
|