Les Inscriptions à la Bibliothèque sont ouvertes en
ligne via le site: https://biblio.enp.edu.dz
Les Réinscriptions se font à :
• La Bibliothèque Annexe pour les étudiants en
2ème Année CPST
• La Bibliothèque Centrale pour les étudiants en Spécialités
A partir de cette page vous pouvez :
Retourner au premier écran avec les recherches... |
Détail de l'auteur
Auteur Kedjar, Bachir
Documents disponibles écrits par cet auteur
Affiner la rechercheDSP-based implementation of an LQR with integral action for a three-phase three-wire shunt active power filter / Kedjar, Bachir in IEEE transactions on industrial electronics, Vol. 56 N° 8 (Août 2009)
[article]
in IEEE transactions on industrial electronics > Vol. 56 N° 8 (Août 2009) . - pp. 2821 - 2828
Titre : DSP-based implementation of an LQR with integral action for a three-phase three-wire shunt active power filter Type de document : texte imprimé Auteurs : Kedjar, Bachir, Auteur ; Kamal Al Haddad, Auteur Article en page(s) : pp. 2821 - 2828 Note générale : Génie électrique Langues : Anglais (eng) Mots-clés : Digital signal processor (DSP) Linear quadratic regulator (LQR) Optimal control Shunt active power filter Index. décimale : 621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X Résumé : This paper presents the design and implementation of a linear quadratic regulator (LQR) with integral action (LQRI) for a three-phase three-wire shunt active filter (SAF). The integral action is added so as to cancel the steady-state errors for reference tracking or disturbance rejection, knowing that the standard LQR provides only proportional gains. The controller is designed to achieve DC bus voltage regulation and harmonics and reactive power compensation. The converter model is set in the d-q rotating reference frame. The latter is augmented with the integral of the q component of the SAF currents and DC bus voltage to achieve integral action. The controller's performance depends on the weighting matrix, which is chosen to ensure satisfactory response. The converter is controlled as a whole, i.e., a multi-input-multioutput system and a fixed pulsewidth modulation at 10 kHz is used to generate the gating signals of the power devices. The system is tested for harmonics, reactive power, and load unbalance compensation for balanced/unbalanced loads. The experimental results obtained with a digital signal processor-based implementation of the controller on the DS1104 of dSPACE show good performance in terms of DC bus voltage regulation (small overshoot and very fast time response) and a low total harmonic distortion of AC line currents. DEWEY : 621.38 ISSN : 0278-0046 En ligne : http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4663692 [article] DSP-based implementation of an LQR with integral action for a three-phase three-wire shunt active power filter [texte imprimé] / Kedjar, Bachir, Auteur ; Kamal Al Haddad, Auteur . - pp. 2821 - 2828.
Génie électrique
Langues : Anglais (eng)
in IEEE transactions on industrial electronics > Vol. 56 N° 8 (Août 2009) . - pp. 2821 - 2828
Mots-clés : Digital signal processor (DSP) Linear quadratic regulator (LQR) Optimal control Shunt active power filter Index. décimale : 621.38 Dispositifs électroniques. Tubes à électrons. Photocellules. Accélérateurs de particules. Tubes à rayons X Résumé : This paper presents the design and implementation of a linear quadratic regulator (LQR) with integral action (LQRI) for a three-phase three-wire shunt active filter (SAF). The integral action is added so as to cancel the steady-state errors for reference tracking or disturbance rejection, knowing that the standard LQR provides only proportional gains. The controller is designed to achieve DC bus voltage regulation and harmonics and reactive power compensation. The converter model is set in the d-q rotating reference frame. The latter is augmented with the integral of the q component of the SAF currents and DC bus voltage to achieve integral action. The controller's performance depends on the weighting matrix, which is chosen to ensure satisfactory response. The converter is controlled as a whole, i.e., a multi-input-multioutput system and a fixed pulsewidth modulation at 10 kHz is used to generate the gating signals of the power devices. The system is tested for harmonics, reactive power, and load unbalance compensation for balanced/unbalanced loads. The experimental results obtained with a digital signal processor-based implementation of the controller on the DS1104 of dSPACE show good performance in terms of DC bus voltage regulation (small overshoot and very fast time response) and a low total harmonic distortion of AC line currents. DEWEY : 621.38 ISSN : 0278-0046 En ligne : http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4663692
Titre : Etude de l'arbre électrique Type de document : texte imprimé Auteurs : Djerroud, Améziane, Auteur ; Kedjar, Bachir, Auteur ; Schreyer, Bogustaw, Directeur de thèse Editeur : [S.l.] : [s.n.] Année de publication : 1984 Importance : 74 f. Présentation : ill. Format : 27 cm. Note générale : Mémoire de Projet de Fin d’Études : Électrotechnique : Alger, École Nationale Polytechnique : 1984
Bibliogr. [1] fLangues : Français (fre) Mots-clés : Arbre électrique -- Etude
Rhéostat de glissementIndex. décimale : PA01184 Résumé : Ce projet consiste l'étude du fonctionnement des différents types d'arbres électriques, notamment la détermination de leurs caractéristiques théoriques.
Les procédés des synchronisation à l'arrêt y sont traités brièvement, les essais constituent une vérification pratiques des allures des caractéristiques de l'arbre électrique avec un rhéostat de glissement.Etude de l'arbre électrique [texte imprimé] / Djerroud, Améziane, Auteur ; Kedjar, Bachir, Auteur ; Schreyer, Bogustaw, Directeur de thèse . - [S.l.] : [s.n.], 1984 . - 74 f. : ill. ; 27 cm.
Mémoire de Projet de Fin d’Études : Électrotechnique : Alger, École Nationale Polytechnique : 1984
Bibliogr. [1] f
Langues : Français (fre)
Mots-clés : Arbre électrique -- Etude
Rhéostat de glissementIndex. décimale : PA01184 Résumé : Ce projet consiste l'étude du fonctionnement des différents types d'arbres électriques, notamment la détermination de leurs caractéristiques théoriques.
Les procédés des synchronisation à l'arrêt y sont traités brièvement, les essais constituent une vérification pratiques des allures des caractéristiques de l'arbre électrique avec un rhéostat de glissement.Exemplaires
Code-barres Cote Support Localisation Section Disponibilité Spécialité Etat_Exemplaire PA01184 PA01184 Papier Bibliothèque centrale Projet Fin d'Etudes Disponible Consultation sur place Documents numériques
DJERROUD.Ameziane_KEDJAR.Bachir.pdfURL