Characteristics and performance analysis of the SPP1 solar power plant Hassi R'mel / Abdelhakim Lakehal (2014)
![]()
Titre : Characteristics and performance analysis of the SPP1 solar power plant Hassi R'mel : air-cooled condensers role Type de document : texte imprimé Auteurs : Abdelhakim Lakehal, Auteur ; Ait Ali, Mohand Ameziane, Directeur de thèse Editeur : [S.l.] : [s.n.] Année de publication : 2014 Importance : 100 f. Présentation : ill. Format : 30 cm. Accompagnement : 1 CD-ROM. Note générale : Mémoire de Projet de Fin d’Études : Génie Mécanique : Alger, École Nationale Polytechnique : 2014
Bibliogr. f. 101-103. - Annexes f. 104-105Langues : Anglais (eng) Mots-clés : SPP1
Condensation temperature Integrated
Solar Combined-CycleIndex. décimale : PM00714 Résumé :
The work presented in this memoire is a performance study of the hybrid solar power plant one (SPP1) located in Hassi R’mel. The aim of this study is to quantify the gains in both power output and thermal efficiency by lowering the temperature of condensation of the steam turbine, and analyze its impacts on the combined-cycle, the heat recovery steam generator also the solar field and the natural gas consumption. A comparison and economics evaluations are presented at the end of this paper.Characteristics and performance analysis of the SPP1 solar power plant Hassi R'mel : air-cooled condensers role [texte imprimé] / Abdelhakim Lakehal, Auteur ; Ait Ali, Mohand Ameziane, Directeur de thèse . - [S.l.] : [s.n.], 2014 . - 100 f. : ill. ; 30 cm. + 1 CD-ROM.
Mémoire de Projet de Fin d’Études : Génie Mécanique : Alger, École Nationale Polytechnique : 2014
Bibliogr. f. 101-103. - Annexes f. 104-105
Langues : Anglais (eng)
Mots-clés : SPP1
Condensation temperature Integrated
Solar Combined-CycleIndex. décimale : PM00714 Résumé :
The work presented in this memoire is a performance study of the hybrid solar power plant one (SPP1) located in Hassi R’mel. The aim of this study is to quantify the gains in both power output and thermal efficiency by lowering the temperature of condensation of the steam turbine, and analyze its impacts on the combined-cycle, the heat recovery steam generator also the solar field and the natural gas consumption. A comparison and economics evaluations are presented at the end of this paper.Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité Spécialité Etat_Exemplaire PM00714A PM00714 Papier + ressource électronique Bibliothèque centrale Projet Fin d'Etudes Disponible Genie_mecanique Consultation sur place/Téléchargeable Documents numériques
![]()
LAKEHAL.Abdelhakim.pdfURL